z-logo
open-access-imgOpen Access
Discrimination of wear and non-wear in infants using data from hip- and ankle-worn devices
Author(s) -
Samuel R. LaMunion,
Scott E. Crouter,
Nicholas T. Broskey,
Abby D. Altazan,
Leanne M. Redman
Publication year - 2020
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0240604
Subject(s) - ankle , physical medicine and rehabilitation , medicine , hip flexion , gait , physical therapy , range of motion , surgery
A key component to analyzing wearable sensor data is identifying periods of non-wear. Traditionally, strings of consecutive zero counts (e.g. >60-minutes) are identified indicating periods of non-movement. The non-movement window length is then evaluated as wear or non-wear. Given that non-movement is not equivalent to non-wear, additional criteria should be evaluated to objectively identify periods of non-wear. Identifying non-wear is especially challenging in infants due to their sporadic movement, sleep frequency, and proportion of caregiver-generated movement. Purpose To use hip- and ankle-worn ActiGraph wGT3X-BT (wGT3X-BT) data to identify non-wear in infants. Methods Fifteen infant participants [mean±SD; age, 8.7±1.7 weeks (range 5.4–11.3 weeks); 5.1±0.8 kg; 56.2±2.1 cm; n = 8 females] wore a wGT3X-BT on the hip and ankle. Criterion data were collected during two, 2-hour directly observed periods in the laboratory. Using raw 30 Hz acceleration data, a vector magnitude and the inclination angle of each individual axis were calculated before being averaged into 1-minute windows. Three decision tree models were developed using data from 1) hip only, 2) ankle only, and 3) hip and ankle combined. Results The hip model classified 86.6% of all minutes (wear and non-wear) correctly (F1 = 75.5%) compared to the ankle model which classified 90.6% of all minutes correctly (F1 = 83.0%). The combined site model performed similarly to the ankle model and correctly classified 90.0% of all minutes (F1 = 80.8%). Conclusion The similar performance between the ankle only model and the combined site model likely indicates that the features from the ankle device are more important for identifying non-wear in infants. Overall, this approach provides an advancement in the identification of device wear status using wearable sensor data in infants.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here