Concurrent heart rate validity of wearable technology devices during trail running
Author(s) -
James W. Navalta,
Jeffrey Montes,
Nathaniel G. Bodell,
Robert W. Salatto,
Jacob W. Manning,
Mark DeBeliso
Publication year - 2020
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0238569
Subject(s) - concurrent validity , heart rate , statistics , accelerometer , limits of agreement , mathematics , physical therapy , physical medicine and rehabilitation , medicine , simulation , computer science , nuclear medicine , blood pressure , internal consistency , operating system , psychometrics
Validation of heart rate responses in wearable technology devices is generally composed of laboratory-based protocols that are steady state in nature and as a result, high accuracy measures are returned. However, there is a need to understand device validity in applied settings that include varied intensities of exercise. The purpose was to determine concurrent heart rate validity during trail running. Twenty-one healthy participants volunteered (female n = 10, [mean (SD)]: age = 31 [ 11 ] years, height = 173.0 [ 7 ] cm, mass = 75.6 [ 13 ] kg). Participants were outfitted with wearable technology devices (Garmin Fenix 5 wristwatch, Jabra Elite Sport earbuds, Motiv ring, Scosche Rhythm+ forearm band, Suunto Spartan Sport watch with accompanying chest strap) and completed a self-paced 3.22 km trail run while concurrently wearing a criterion heart rate strap (Polar H7 heart rate monitor). The trail runs were out-and-back with the first 1.61 km in an uphill direction, and the 1.61 return being downhill in nature. Validity was determined through three methods: Mean Absolute Percent Error (MAPE), Bland-Altman Limits of Agreement (LOA), and Lin’s Concordance Coefficient (r C ). Validity measures overall are as follows: Garmin Fenix 5 (MAPE = 13%, LOA = -32 to 162, r C = 0.32), Jabra Elite Sport (MAPE = 23%, LOA = -464 to 503, r C = 0.38), Motiv ring (MAPE = 16%, LOA = -52 to 96, r C = 0.29), Scosche Rhythm+ (MAPE = 6%, LOA = -114 to 120, r C = 0.79), Suunto Spartan Sport (MAPE = 2%, LOA = -62 to 61, r C = 0.96). All photoplethysmography-based (PPG) devices displayed poor heart rate agreement during variable intensity trail running. Until technological advances occur in PPG-based devices allowing for acceptable agreement, heart rate in outdoor environments should be obtained using an ECG-based chest strap that can be connected to a wristwatch or other comparable receiver.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom