z-logo
open-access-imgOpen Access
A simultaneous optical and electrical in-vitro neuronal recording system to evaluate microelectrode performance
Author(s) -
Zaid Aqrawe,
Nitish Patel,
Yukti Vyas,
Mahima Bansal,
Johanna M. Montgomery,
Jadranka Travaš-Sejdić,
Darren Svirskis
Publication year - 2020
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0237709
Subject(s) - microelectrode , materials science , multielectrode array , signal (programming language) , polystyrene sulfonate , pedot:pss , optoelectronics , optode , electrode , computer science , biomedical engineering , nanotechnology , optics , fluorescence , chemistry , physics , medicine , programming language , layer (electronics)
Objectives In this paper, we aim to detail the setup of a high spatio-temporal resolution, electrical recording system utilising planar microelectrode arrays with simultaneous optical imaging suitable for evaluating microelectrode performance with a proposed ′performance factor′ metric. Methods Techniques that would facilitate low noise electrical recordings were coupled with voltage sensitive dyes and neuronal activity was recorded both electrically via a customised amplification system and optically via a high speed CMOS camera. This technique was applied to characterise microelectrode recording performance of gold and poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) coated electrodes through traditional signal to noise (SNR) calculations as well as the proposed performance factor. Results Neuronal activity was simultaneously recorded using both electrical and optical techniques and this activity was confirmed via tetrodotoxin application to inhibit action potential firing. PEDOT/PSS outperformed gold using both measurements, however, the performance factor metric estimated a 3 fold improvement in signal transduction when compared to gold, whereas SNR estimated an 8 fold improvement when compared to gold. Conclusion The design and functionality of a system to record from neurons both electrically, through microelectrode arrays, and optically via voltage sensitive dyes was successfully achieved. Significance The high spatiotemporal resolution of both electrical and optical methods will allow for an array of applications such as improved detection of subthreshold synaptic events, validation of spike sorting algorithms and a provides a robust evaluation of extracellular microelectrode performance.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here