z-logo
open-access-imgOpen Access
Safety, prosthesis wearing time and health-related quality of life of lower extremity bone-anchored prostheses using a press-fit titanium osseointegration implant: A prospective one-year follow-up cohort study
Author(s) -
Robin Atallah,
Henk van de Meent,
Luc Verhamme,
Jan Paul M. Frölke,
Ruud A. Leijendekkers
Publication year - 2020
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0230027
Subject(s) - osseointegration , medicine , prosthesis , prospective cohort study , dentistry , implant , quality of life (healthcare) , cohort study , physical therapy , surgery , nursing
Background We described safety and functional one-year follow-up outcomes of individuals with lower limb amputation treated with bone-anchored prostheses using titanium press-fit osseointegration implants. Methods All consecutive individuals treated between March 2015 and June 2018 with curved osseointegration femur implant (OFI-C) indicated for a long femoral remnant, gamma osseointegration femur implant (OFI-Y) indicated for a short femoral remnant, or osseointegration tibia implant (OTI) were eligible for this study. All adverse events were evaluated, infections were graded as follows: grade 1 and 2: low- and high-grade soft tissue infection, respectively, grade 3: deep bone infection, grade 4: septic implant failure. Functional outcome measures included prosthesis wearing time (PUS), health-related quality of life (GS), and the overall situation as an amputee (GS Q3); evaluated with the Questionnaire of persons with trans-femoral amputation (Q-TFA) before surgery and at one-year follow-up. Results Ninety of 91 individuals were included (mean age: 54±14 yrs, 26 females); treated with 53, 16 and 21 OFI-C, OFI-Y and OTI, respectively. Soft tissue infections (grade 1: 11 events, grade 2: 10 events) were treated successfully with antibiotics except in two (OFI-C and OFI-Y), who required additional surgery due to recurrent stoma irritation and peri-stoma abscess drainage. One individual with dysvascular amputation (OTI) developed septic implant loosening and occlusion of the femoral artery resulting in a transfemoral amputation. No aseptic loosening’s occurred. One individual (OFI-Y) required stoma surgical refashioning due to soft tissue redundancy. At baseline mean ±SD and median (25 th to 75 th PCTL) Q-TFA PUS and GS were 52±39, 52(7–90) and 40±19, 42(25–50) and improved significantly to 88±18, 90 (90–100) and 71±15, 75 (67–83) at one-year follow-up. The GS Q3 improved over time. Conclusion Titanium osseointegration implants can be safely used within a one-year follow-up period. The performance improved compared to the use of a socket-suspended prosthesis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom