Intra-arterial catheter-directed CT angiography for assessment of endovascular aortic aneurysm repair
Author(s) -
Marco V. Usai,
Mirjam Gerwing,
Antje Gottschalk,
Peter Sporns,
Walter Heindel,
Alexander Oberhuber,
Moritz Wildgruber,
Michael Köhler
Publication year - 2019
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0221375
Subject(s) - medicine , creatinine , clinical endpoint , catheter , renal function , endovascular aneurysm repair , radiology , computed tomography angiography , aorta , angiography , aortic aneurysm , aneurysm , surgery , abdominal aortic aneurysm , randomized controlled trial
Objective To compare the efficacy and safety as well as associated image quality of catheter-directed CT angiography (CCTA) with a low dose of iodine contrast agent compared to intravenous CTA in patients undergoing endovascular aortic aneurysm repair (EVAR). Methods Retrospective data analysis of 92 patients undergoing EVAR between January 2009 and December 2017 was performed. Patients were divided in two groups; those receiving CTA (n = 59) after intravenous contrast agent application and those receiving CCTA (n = 33) via an intraarterial catheter placed in the descending aorta. Demographic and cardiovascular risk factors as well as renal function parameters before, immediately after and 6–60 months after EVAR were evaluated. As primary endpoint, changes in serum creatinine levels in the two groups were evaluated. Secondary endpoints encompassed complications associated with intraarterial catheter placement. Objective (signal-to-noise ratios) and subjective image quality (5-point Likert scale) were compared. Results Amount of contrast medium was significantly lower in CCTA compared to i.v. CTA (23 ± 7 ml vs. 119 ± 15 ml, p<0.0001). Patients undergoing catheter-directed CTA had higher baseline creatinine values compared to the group with intravenous iodine application (1.9 ± 0.6 mg/dl vs. 1.3 ± 0.5 mg/dl; p<0.0001). Follow-up serum creatinine levels however did not show significant alterations between the two groups (1.9 ± 0.4 mg/dl vs. 1.3 ± 0.5 mg/dl). No major complications were detected in the CCTA group. Signal-to-noise ratio (SNR) was comparable between i.v. CTA and CCTA (8.5 ± 4.6 vs. 7.7 ± 4.0; p = 0.37) and subjective image similarly revealed no differences with a good interobserver agreement (ICC = 0.647). Conclusions Catheter-directed CTA is safe and provides comparable image quality with a substantial retrenchment of the needed amount of iodine-based contrast medium. However, no benefit of the reduced contrast medium protocol with respect to renal function was observed.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here