z-logo
open-access-imgOpen Access
A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography
Author(s) -
Kai Jiang,
Christopher M. Ferguson,
Abdelrhman Abumoawad,
Ahmed Saad,
Stephen C. Textor,
Lilach O. Lerman
Publication year - 2019
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0219605
Subject(s) - renal function , perfusion , medicine , nuclear medicine , reproducibility , compartment (ship) , renal blood flow , kidney , magnetic resonance imaging , dynamic contrast enhanced mri , blood flow , perfusion scanning , urology , radiology , chemistry , oceanography , chromatography , geology
Objectives To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). Methods This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Thirty-eight patients with essential hypertension (EH, n = 13) or atherosclerotic renal artery stenosis (ARAS, n = 25) underwent renal DCE-CT for GFR and perfusion measurement using a modified two-compartment model. Iothalamate clearance was used to measure reference total GFR, which was apportioned into single-kidney GFR by renal blood flow. Renal perfusion was also calculated using a conventional deconvolution algorithm. Validation of GFR and perfusion and inter-observer reproducibility, were conducted by using the Pearson correlation and Bland-Altman analysis. Results Both the two-compartment model and iothalamate clearance detected in ARAS patients lower GFR in the stenotic compared to the contralateral and EH kidneys. GFRs measured by DCE-CT and iothalamate clearance showed a close match (r = 0.94, P<0.001, and mean difference 2.5±12.2mL/min). Inter-observer bias and variation in model-derived GFR (r = 0.97, P<0.001; mean difference, 0.3±7.7mL/min) were minimal. Renal perfusion by deconvolution agreed well with that by the compartment model when the blood transit delay from abdominal aorta to kidney was negligible. Conclusion The proposed two-compartment model faithfully depicts contrast dynamics using DCE-CT and may provide a reliable tool for measuring human single-kidney GFR and perfusion.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here