Background Regional anticoagulation with citrate during renal replacement therapy (RRT) reduces the risk of bleeding, extends dialyzer lifespan and is cost-effective. Therefore, current guidelines recommend its use if patients are not anticoagulated for another reason and if there are no contraindications against citrate. RRT with regional citrate anticoagulation has been established in critically ill patients as continuous veno-venous hemodialysis (CVVHD) to reduce citrate load. However, CVVHD is inferior regarding middle molecule clearance compared to continuous veno-venous hemofiltration (CVVH). The use of a high cut-off dialyzer in CVVHD may thus present an option for middle molecule clearance similar to CVVH. This may allow combining the advantages of both techniques. Methods In this prospective, randomized, single-blinded single-center-trial, sixty patients with acute renal failure and established indication for renal replacement therapy were randomized 1:1 into two groups. The control group was put on CVVHD using regional citrate anticoagulation and a high-flux dialyzer, while the intervention group was on CVVHD using regional citrate anticoagulation and a high-cut-off dialyzer. The concentrations of urea, creatinine, β 2 -microglobulin, myoglobin, interleukin 6 and albumin were measured pre- and post-dialyzer 1, 6, 12, 24 and 48 hours after initiating CVVHD. Results Mean plasma clearance for β 2 -microglobulin was 19.6±5.8 ml/min in the intervention group vs. 12.2±3.6 ml/min in the control group (p<0.001). For myoglobin (8.0±4.5 ml/min vs. 0.2±3.6 ml/min, p<0.001) and IL-6 (1.5±4.3 vs. -2.5±3.5 ml/min, p = 0.002) a higher mean plasma clearance using high-cut-off dialyzer could be detected too, but no difference for urea, creatinine and albumin could be observed concerning this parameter between the two groups. Conclusion CVVHD using a high cut-off dialyzer results in more effective middle molecule clearance than that with high-flux dialyzer. Trial registration German Clinical Trials Register ( DRKS00005254 , registered 26th November 2013)

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here