z-logo
open-access-imgOpen Access
Comparisons of early vascular reactions in biodegradable and durable polymer-based drug-eluting stents in the porcine coronary artery
Author(s) -
Takeshi Ijichi,
Gaku Nakazawa,
Sho Torii,
Hirofumi Nagamatsu,
Ayako Yoshikawa,
Junko Souba,
Atsushi Isobe,
Hitomi Hagiwara,
Yuji Ikari
Publication year - 2019
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0209841
Subject(s) - masson's trichrome stain , fibrin , medicine , h&e stain , trichrome , stent , trichrome stain , drug eluting stent , biodegradable polymer , surgery , staining , pathology , materials science , restenosis , polymer , immunohistochemistry , immunology , composite material
Current drug-eluting stents have abluminal polymer coating; however, thrombus formation in these compared with that in uniformly coated stents remains controversial. We evaluated thrombus formation and early endothelialization after using abluminal biodegradable polymer-coated sirolimus- (BP-SES), and everolimus-eluting stents (BP-EES) versus a durable polymer-coated everolimus-eluting stent (DP-EES) in an in vivo setting. BP-SES, BP-EES, and DP-EES (n = 6 each) were implanted in coronary arteries of 12 mini-pigs that were then sacrificed after 7 and 10 days. Stents were stained with hematoxylin and eosin, and a combined Verhoeff and Masson trichrome stain. Areas of fibrin deposition were digitally detected and measured with off-line morphometric software. Stents were investigated for re-endothelialization by transmission electron microscopy. At 7 days, histological analysis revealed the lowest area of fibrin deposition in BP-SES (BP-SES vs. BP-EES vs. DP-EES; 0.10 ± 0.06 mm 2 vs. 0.15 ± 0.07 mm 2 vs. 0.19 ± 0.06 mm 2 , p = 0.0004). At 10 days, the area of fibrin deposition was significantly greater in DP-EES (0.13 ± 0.04 mm 2 vs. 0.14 ± 0.05 mm 2 vs. 0.19 ± 0.08 mm 2 , p = 0.007). Endothelial cells in BP-SES demonstrated a significantly greater number of tight junctions than those in DP-EES according to by transmission electron microscopy for both days ( p <0.05). Various parameters, including an inflammatory reaction and neointimal formation, were comparable among the groups at 7 and 10 days. An abluminal biodegradable polymer-coated SES showed the least fibrin deposition and greatest endothelial cell recovery at an early stage following implantation in the coronary arteries of mini-pigs.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom