z-logo
open-access-imgOpen Access
Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study
Author(s) -
Sung Hoon Kim,
Jeong-Hoon Kwon,
Youn-Jung Kim,
Hyung-Joo Lee,
Hyungil Seo,
Seung Bok Lim,
Segyeong Joo,
Dong-Woo Seo,
Youn-Jung Kim,
Sang-Bum Hong
Publication year - 2018
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0207445
Subject(s) - intubation , laryngoscopy , airway , medicine , anesthesia , airway management , endotracheal intubation , physical therapy
Direct laryngoscopy using a Macintosh laryngoscope is the most widely used approach; however, this skill is not easy for novices and trainees. We evaluated the performance of novices using a laryngoscope with a three-dimensional (3D)-printed ergonomic grip on an airway manikin. Forty second-year medical students were enrolled. Endotracheal intubation was attempted using a conventional Macintosh laryngoscope with or without a 3D-printed ergonomic support grip. Primary outcomes were intubation time and overall success rate. Secondary outcomes were number of unsuccessful attempts, first-attempt success rate, airway Cormack-Lehane (CL) grade, and difficulty score. In the easy airway scenario, intubation time, and the overall success rate were similar between two group. CL grade and ease-of-use scores were significantly better for those using the ergonomic support grip ( P < 0.05). In the difficult airway scenario, intubation time (49.7±37.5 vs. 35.5±29.2, P = 0.013), the first-attempt success rate (67.5% vs. 90%, P = 0.029), number of attempts (1.4±0.6 vs. 1.1±0.4, P = 0.006), CL grade (2 [ 2 , 2 ] vs. 2 [ 1 , 1 ], P = 0.012), and ease-of-use scores (3.5 [ 2 , 4 ] vs. 4 [ 3 , 5 ], P = 0.008) were significantly better for those using the ergonomic support grip. Linear mixed model analysis showed that the ergonomic support grip had a favorable effect on CL grade ( P <0.001), ease-of-use scores ( P <0.001), intubation time ( P = 0.015), and number of intubation attempts ( P = 0.029). Our custom 3D-printed ergonomic laryngoscope support grip improved several indicators related to the successful endotracheal intubation in the easy and difficult scenario simulated on an airway manikin. This grip may be useful for intubation training and practice.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here