z-logo
open-access-imgOpen Access
Serum IL-6 in combination with synovial IL-6/CRP shows excellent diagnostic power to detect hip and knee prosthetic joint infection
Author(s) -
Jiří Gallo,
Michal Svoboda,
Jana Zapletalová,
Jitka Prošková,
Jarmila Juráňová
Publication year - 2018
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0199226
Subject(s) - knee joint , medicine , synovial fluid , immunology , pathology , osteoarthritis , surgery , alternative medicine
Background The diagnosis of prosthetic joint infection (PJI) is still a challenge in some patients after total joint replacement. Interleukin-6 (IL-6) strongly participates in the arrangement of the host-bacteria response. Therefore, increased levels of IL-6 should accompany every PJI. Purpose The aim of the study was to show diagnostic characteristics of serum IL-6 for the diagnosis of prosthetic joint infection (PJI). We also compared the diagnostic values of serum IL-6 with synovial IL-6 (sIL-6) and synovial C-reactive protein (sCRP). Study design We performed a prospective study of 240 patients in whom serum IL-6 was determined before total hip (n = 124) or knee (n = 116) reoperations. The PJI diagnosis was based on the MSIS (Musculoskeletal Infection Society) criteria (2011). Receiver operating characteristic plots were constructed for IL-6, sIL-6, and sCRP. Results PJI was diagnosed in 93 patients, and aseptic revision was diagnosed in 147 patients. The AUC (area under curve) for IL-6 was 0.938 (95% CI; 0.904–0.971). The optimal IL-6 cut-off value for PJI was 12.55 ng/L. Positive and negative likelihood ratios for IL-6 were 8.24 (95% CI; 4.79–14.17) and 0.15 (95% CI; 0.09–0.26), respectively. The optimal sIL-6 and sCRP cut-off values were 20,988 ng/L and 8.80 mg/L, respectively. Positive and negative likelihood ratios for sIL-6 were 40.000 (95% CI; 5.7–280.5) and 0.170 (95% CI; 0.07–0.417), respectively. Negative likelihood ratio for sCRP was 0.083 (95% CI; 0.022–0.314). Conclusions The present study identified the cut-off values for serum/synovial IL-6 and synovial CRP for diagnostics of PJI at the site of THA and TKA and separately for each site. The diagnostic odds ratio for serum/synovial IL-6 and synovial CRP is very good. Simultaneous positivity of serum IL-6 either with synovial IL-6 or synovial CRP almost excludes false negative detection of PJI at the site of interest.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here