z-logo
open-access-imgOpen Access
Accuracy of a screening tool for medication adherence: A systematic review and meta-analysis of the Morisky Medication Adherence Scale-8
Author(s) -
Sun Jae Moon,
Weon Young Lee,
Jin-soo Hwang,
Yeon Pyo Hong,
Donald E. Morisky
Publication year - 2017
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0187139
Subject(s) - medicine , meta analysis , intraclass correlation , confidence interval , cronbach's alpha , medication adherence , psychometrics , clinical psychology
Background This systematic review examined the reliability and validity of the Morisky Medication Adherence Scale-8 (MMAS-8), which has been widely used to assess patient medication adherence in clinical research and medical practice. Methods Of 418 studies identified through searching 4 electronic databases, we finally analyzed 28 studies meeting the selection criteria of this study regarding the reliability and validity of MMAS-8 including sensitivity and specificity. Meta-analysis for Cronbach’s α, intraclass correlation coefficient (ICC), sensitivity and specificity to detect a patient with nonadherence to medication were performed. The pooled estimates for Cronbach’s α and ICC were calculated using the random-effects weighted T transformation. A bivariate random-effects model was used to estimate pooled sensitivity and specificity. Findings The pooled Cronbach's α estimate for type 2 diabetes group in 7 studies and osteoporosis group in 3 studies were 0.67 (95% Confidence Interval(CI), 0.65 to 0.69) and 0.77 (95% CI, 0.72 to 0.83), respectively. With regard to test-retest, the pooled ICC for type 2 diabetes group in 3 studies and osteoporosis group in 2 studies were 0.81 (95% CI, 0.75 to 0.85) and 0.80 (95% CI, 0.74 to 0.85). For a cut-off value of 6, the pooled sensitivity and specificity in 12 studies were 0.43 (95% CI, 0.33 to 0.53) and 0.73 (95% CI, 0.68 to 0.78), respectively. Conclusions The MMAS-8 had acceptable internal consistency and reproducibility in a few diseases like type 2 diabetes. Using the cut-off value of 6, criterion validity was not enough good to validly screen a patient with nonadherence to medication. However, this study did not calculated a pooled estimate for criterion validity using the higher values than 6 as a cut-off value since most of included individual studies did not report criterion validity based on those values.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here