Light transmission aggregometry using pre-coated microtiter plates and a Victor X5 plate reader
Author(s) -
Pernille Just Vinholt,
Mads Nybo,
Camilla Brødsgaard Nielsen,
AnneMette Hvas
Publication year - 2017
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0185675
Subject(s) - absorbance , microtiter plate , plate reader , chemistry , chromatography , platelet , agonist , adenosine diphosphate , platelet aggregation , thrombin , platelet poor plasma , biochemistry , receptor , immunology , optics , medicine , fluorescence , physics
Background Light transmission aggregometry (LTA) can be performed with microtiter plates (96-well LTA). When conducting LTA, an agonist is added to platelet-rich plasma and the sample is shaken for minutes after which absorbance readings are done. Platelet aggregation is detected as decrease in absorbance. However, the classical method is cumbersome and therefore microtiter plates can be used for concomitant testing of multiple samples. Furthermore, it would be convenient to prepare the plate in advance of platelet aggregation testing. Aim: The aim of the present study was to establish a simplified 96-well LTA protocol, where plates were pre-coated with agonists and stored at -80 C until use. Results We developed and validated a protocol for 96-well LTA using a Victor X5 plate reader and pre-coated microtiter plates. The minimum requirement of platelet-rich plasma was 45 μL per sample and the sample platelet count should not be below 100 x109/L. Optimal absorbance reading was 595 nm wavelengths. Platelet aggregation results were higher at 37°C than at room temperature. Platelet adherence to wells after stimulation was observed; it was not avoided by pre-coating of the wells with gelatin. A range of up to 7 concentrations for each agonist (collagen, arachidonic acid, adenosine diphosphate, thrombin receptor-activating peptide and protease-activated receptor-4) was tested concomitantly. A transient rise in platelet aggregation was observed after 2 minutes of shaking in some samples with low agonist concentration, and platelet aggregation was optimal after 10 minutes of shaking for samples with high agonist concentration. Plates could be stored at -80°C for 15 days without significant change in the platelet aggregation results. Conclusion The 96-well LTA is suitable for platelet aggregation testing and a range of agonist concentrations can be concomitantly tested.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here