Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study
Author(s) -
Toshihide Ikeda,
Kanji Uchida,
Yasuhiro Yamauchi,
Takahide Nagase,
Koji Oba,
Yosuke Yamada
Publication year - 2017
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0172421
Subject(s) - medicine , anesthetic , anesthesia , airway , airway resistance , airway obstruction , spirometry , ventilation (architecture) , asthma , mechanical engineering , engineering
Surgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilation management during general anesthesia. So far, there have been no attempts to calculate airway resistance using flow-volume curves. Therefore, we performed a prospective, observational study to investigate the relationship between pre-anesthetic and intra-anesthetic airway resistance in patients scheduled for surgery under general anesthesia. We calculated pre-anesthetic and intra-anesthetic airway resistance in each patient, based on the slopes of flow-volume curves obtained prior to and during general anesthesia. We also calculated endotracheal tube resistance to correct the intra-anesthetic airway resistance values calculated. A total of 526 patients were included in the study, and 98 patients had a forced expiratory volume in the first second/forced vital capacity ratio of < 70%. Pre-anesthetic airway resistance was significantly higher in patients with airflow obstruction than in those without airflow obstruction ( p < 0.001), whereas no significant difference in intra-anesthetic airway resistance was found between patients with and without airflow obstruction during mechanical ventilation ( p = 0.48). Pre-anesthetic and intra-anesthetic airway resistance values were closer to each other in patients without airflow obstruction, with a mean difference < 1.0 cmH 2 O L -1 s -1 , than in those with airflow obstruction, although these respiratory parameters were significantly different ( p < 0.001). Intra-anesthetic airway resistance was not related to the FEV1/FVC ratio, regardless of the degree to which the FEV1/FVC ratio reflected pre-anesthetic airway resistance. As compared with patients with airflow obstruction, the mean difference between pre-anesthetic and intra-anesthetic airway resistance was small in patients without airflow obstruction.