z-logo
open-access-imgOpen Access
3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry
Author(s) -
A.R. Barbeiro,
Ana Ureba,
J.A. Baeza,
R. Linares,
M. Perucha,
Elisa Jiménez-Ortega,
S. Velázquez,
Juán Carlos Pachón Mateos,
Antonio Leal
Publication year - 2016
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0166767
Subject(s) - imaging phantom , monte carlo method , radiation treatment planning , dosimetry , computer science , ionization chamber , voxel , histogram , simulation , nuclear medicine , algorithm , computational science , physics , radiation therapy , mathematics , optics , artificial intelligence , ionization , statistics , ion , quantum mechanics , medicine , image (mathematics)
A model based on a specific phantom, called QuAArC, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (VMAT). This model uses the high accuracy provided by the Monte Carlo (MC) simulation of log files and allows the experimental feedback from the high spatial resolution of films hosted in QuAArC. This cylindrical phantom was specifically designed to host films rolled at different radial distances able to take into account the entrance fluence and the 3D dose distribution. Ionization chamber measurements are also included in the feedback process for absolute dose considerations. In this way, automated MC simulation of treatment log files is implemented to calculate the actual delivery geometries, while the monitor units are experimentally adjusted to reconstruct the dose-volume histogram (DVH) on the patient CT. Prostate and head and neck clinical cases, previously planned with Monaco and Pinnacle treatment planning systems and verified with two different commercial systems (Delta4 and COMPASS), were selected in order to test operational feasibility of the proposed model. The proper operation of the feedback procedure was proved through the achieved high agreement between reconstructed dose distributions and the film measurements (global gamma passing rates > 90% for the 2%/2 mm criteria). The necessary discretization level of the log file for dose calculation and the potential mismatching between calculated control points and detection grid in the verification process were discussed. Besides the effect of dose calculation accuracy of the analytic algorithm implemented in treatment planning systems for a dynamic technique, it was discussed the importance of the detection density level and its location in VMAT specific phantom to obtain a more reliable DVH in the patient CT. The proposed model also showed enough robustness and efficiency to be considered as a pre-treatment VMAT verification system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here