z-logo
open-access-imgOpen Access
Accuracy improvement of single-sample calibration laser-induced breakdown spectroscopy with self-absorption correction
Author(s) -
Fan Deng,
Zhenlin Hu,
Deng Zhang,
Feng Chen,
Xuechen Niu,
Junfei Nie,
Qingdong Zeng,
Lianbo Guo
Publication year - 2022
Publication title -
optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.394
H-Index - 271
ISSN - 1094-4087
DOI - 10.1364/oe.446334
Subject(s) - laser induced breakdown spectroscopy , materials science , spectroscopy , calibration , optics , attenuation coefficient , analytical chemistry (journal) , calibration curve , absorption (acoustics) , plasma , laser , composite material , chemistry , mathematics , detection limit , physics , chromatography , statistics , quantum mechanics
The single sample calibration laser-induced breakdown spectroscopy (SSC-LIBS) is quite suitable for the fields where the standard sample is hard to obtain, including space exploration, geology, archaeology, and jewelry identification. But in practice, the self-absorption effect of plasma destroys the linear relationship of spectral intensity and element concentration based on the Lomakin-Scherbe formula which is the guarantee of the high accuracy of the SSC-LIBS. Thus, the self-absorption effect limits the quantitative accuracy of SSC-LIBS greatly. In this work, an improved SSC-LIBS with self-absorption correction (SSC-LIBS with SAC) is proposed for the promotion of quantitative accuracy of SSC-LIBS. The SSC-LIBS with SAC can correct the intensity ratio of spectral lines in the calculation of SSC-LIBS through relative self-absorption coefficient K without complicated preparatory information. The alloy samples and pressed ore samples were used to verify the effect of the SSC-LIBS with SAC. Compared with SSC-LIBS, for alloy samples, the average RMSEP and average ARE of SSC-LIBS with SAC decreased from 0.83 wt.% and 13.75% to 0.40 wt.% and 4.06%, respectively. For the pressed ore samples, the average RMSEP and average ARE of SSC-LIBS with SAC decreased from 4.77 wt.% and 90.48% to 2.34 wt.% and 14.60%. The experimental result indicates that SSC-LIBS with SAC has a great improvement of quantitative accuracy and better universality compared with traditional SSC-LIBS, which is a mighty promotion of the wide application of SSC-LIBS.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom