z-logo
open-access-imgOpen Access
Space-division-multiplexed catadioptric integrated backlight and symmetrical triplet-compound lenticular array based on ORM criterion for 90-degree viewing angle and low-crosstalk directional backlight 3D light-field display
Author(s) -
Chao Gao,
Xinzhu Sang,
Xunbo Yu,
Xin Gao,
Jingyan Du,
Boyang Liu,
Li Liu,
Peiren Wang,
Binbin Yan
Publication year - 2020
Publication title -
optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.394
H-Index - 271
ISSN - 1094-4087
DOI - 10.1364/oe.406009
Subject(s) - backlight , catadioptric system , optics , crosstalk , field of view , light field , multiplexing , physics , ray , computer science , liquid crystal display , telecommunications , lens (geology)
A novel optical reverse mapping (ORM) method and an ORM criterion are proposed to evaluate the relevance between the directional backlight (DB) 3D light-field display system aberration and the crosstalk. Based on the ORM criterion, the space-division-multiplexed catadioptric integrated backlight (SCIB) and symmetrical triplet-compound lenticular array (triplet LA) are designed. The SCIB is composed of hybrid Fresnel integrated backlight unit (hybrid Fresnel unit) and space-division-multiplexed microprism unit (microprism unit). The hybrid Fresnel unit is used to provide the directional light, and the divergence angle is 2.4-degrees. The average uniformity of 83.02% is achieved. The microprism unit is used to modulate the directional light distribution into three predetermined directions to establish a 90-degree viewing area. Combined with SCIB, the triplet LA is used to suppress the aberrations and reduce the crosstalk. In the experiment, a DB 3D light-field display system based on SCIB and triplet LA is set up. The displayed light-field 3D image can be observed in a 90-degree viewing angle. Compared to the conventional DB 3D display system, the light-field 3D image is aberration-suppressed, and the SSIM values are improved from 0.8462 to 0.9618. Meanwhile, the crosstalk measurement results show that the average crosstalk is 3.49%. The minimum crosstalk is 2.31% and the maximum crosstalk is 4.52%. The crosstalk values in 90-degree are lower than 5%.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom