z-logo
open-access-imgOpen Access
Inverse filtering approach to measure directional in-plane modulation transfer function using a sphere phantom for a digital tomosynthesis system
Author(s) -
Changwoo Lee,
Jongduk Baek
Publication year - 2017
Publication title -
optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.394
H-Index - 271
ISSN - 1094-4087
DOI - 10.1364/oe.25.017280
Subject(s) - imaging phantom , tomosynthesis , optical transfer function , optics , plane (geometry) , physics , image plane , projection (relational algebra) , iterative reconstruction , measure (data warehouse) , computer science , computer vision , mathematics , mammography , algorithm , geometry , image (mathematics) , medicine , cancer , database , breast cancer
We propose a method to measure the directional in-plane modulation transfer function (MTF) of a digital tomosynthesis system using a sphere phantom. To assess the spatial resolution of an in-plane image of the tomosynthesis system, projection data of a sphere phantom were generated within a limited data acquisition range of 40°, and reconstructed by the FDK algorithm. To measure the in-plane MTF, we divided the Fourier transform of the reconstructed sphere phantom by that of the ideal sphere phantom, and then performed plane integral along the fz-direction. When dividing, small values in the denominator can introduce estimation errors, and these errors were reduced by the proposed method. To evaluate the performance of the proposed method, the in-plane MTF estimated by simulation and experimental data was compared to the ideal in-plane MTF generated by computer simulations using a point object. For quantitative evaluation, we measured frequency values at half-maximum and full-maximum of the directional in-plane MTF along the three different directions (i.e., f 0° -, f 30° -, and f 60° -directions) and compared them with those of the ideal in-plane MTF. Although the sphere phantom has been regarded as an inappropriate object due to the anisotropic characteristics of tomosynthesis image, our results show that the proposed method has a reliable estimation performance, demonstrating the sphere phantom is still suitable for measuring the directional in-plane MTF for a digital tomosynthesis system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom