Measurements of the gain medium temperature in an operating Cs DPAL
Author(s) -
B. V. Zhdanov,
Matthew D. Rotondaro,
M. K. Shaffer,
R. J. Knize
Publication year - 2016
Publication title -
optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.394
H-Index - 271
ISSN - 1094-4087
DOI - 10.1364/oe.24.019286
Subject(s) - lasing threshold , optics , interferometry , materials science , quenching (fluorescence) , laser , mach–zehnder interferometer , optoelectronics , physics , fluorescence
A Mach-Zehnder interferometer was used for contactless measurement of the temperature of the gain medium within a static cell of Cs DPAL. The maximum temperature recorded approached 700° C leading to a significant degradation of laser performance. This work also examined lasing and non-lasing heat deposition and has shown that as much as 85% of the heating in a DPAL gain medium can be attributed to quenching.