z-logo
open-access-imgOpen Access
Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors
Author(s) -
Jian Li,
Xiaoling Chen,
Liqiao Tian,
Lian Feng
Publication year - 2015
Publication title -
optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.394
H-Index - 271
ISSN - 1094-4087
DOI - 10.1364/oe.23.001829
Subject(s) - remote sensing , radiometric calibration , bidirectional reflectance distribution function , responsivity , optics , environmental science , calibration , satellite , orbital mechanics , radiative transfer , stray light , radiometric dating , radiometry , physics , detector , geology , reflectivity , quantum mechanics , astronomy
The radiometric stability of satellite sensors is crucial for generating highly consistent remote sensing measurements and products. We have presented a radiometric responsivity tracking method designed especially for optical sensors without on-board calibration systems. Using a temporally stable desert site with high reflectance, the sensor responsivity was simulated using the Second Simulation of the Satellite Signal in the Solar Spectrum (6S) radiative transfer model (RTM) with information from validated MODIS atmospheric data. Next, radiometric responsivity drifting was identified using a linear regression of the time series bidirectional reflectance distribution function (BRDF) normalized coefficients. The proposed method was applied to Chinese HJ-1A/1B charge-coupled device (CCD) sensors, which have been on-orbit operations for more than 5 years without continuous assessment of their radiometric performance. Results from the Dunhuang desert site between 2008 and 2013 indicated that the CCD sensors degraded at various rates, with the most significant degradation occurring in the blue bands, ranging from 2.8% to 4.2% yr -1 . The red bands were more stable, with a degradation rate of 0.7-3.1% yr -1 . A cross-sensor comparison revealed the least degradation for the HJ-1A CCD1 (blue: 2.8%; green: 2.8%; red: 0.7%; and NIR: 0.9% yr -1 ), whereas the degradation of HJ-1B CCD1 was most pronounced (blue: 3.5%; green: 4.1%; red: 2.3%; and NIR: 3.4% yr -1 ). The uncertainties of the method were evaluated theoretically based on the propagation of uncertainties from all possible sources of the RT simulations. In addition, a cross comparison with matchup ground-based absolute calibration results was conducted. The comparison demonstrated that the method was useful for continuously monitoring the radiometric performance of remote sensors, such as HJ-1A/1B CCD and GaoFen (GF) series (China's latest high-definition Earth observation satellite), and indicated the potential use of the method for high-precision absolute calibration.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here