Subject(s) - wavefront , optics , human eye , image quality , front (military) , computer science , quality (philosophy) , computer vision , physics , image (mathematics) , quantum mechanics , meteorology
Shack-Hartmann wave-front sensing has been successfully applied to many fields of optical testing including the human eye itself. We propose wave-front measurement for testing protective eye wear for production control and investigation of aberrations. Refractive power data is derived from the wave-front data and compared to a subjective measurement technique based on a focimeter. Additional image quality classification was performed with a multivariate model using objective parameters to resample a subjectively determined visual quality. Wave-front measurement advances optical testing of protective eye wear and may be used for objective quality control.