z-logo
open-access-imgOpen Access
Retinal thermal damage threshold dependence on exposure duration for the transitional near-infrared laser radiation at 1319 nm
Author(s) -
Jiarui Wang,
Lei Jiao,
Xiaomin Jing,
Hongxia Chen,
Xiaoyun Hu,
Zaifu Yang
Publication year - 2016
Publication title -
biomedical optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.362
H-Index - 86
ISSN - 2156-7085
DOI - 10.1364/boe.7.002016
Subject(s) - laser , ed50 , optics , retinal , materials science , radiation , laser safety , chemistry , ophthalmology , physics , medicine , biochemistry , in vitro
The retinal damage effects induced by transitional near-infrared (NIR) lasers have been investigated for years. However, the damage threshold dependence on exposure duration has not been revealed. In this paper, the in-vivo retinal damage ED50 thresholds were determined in chinchilla grey rabbits for 1319 nm laser radiation for exposure durations from 0.1 s to 10 s. The incident corneal irradiance diameter was fixed at 5 mm. The ED50 thresholds given in terms of the total intraocular energy (TIE) for exposure durations of 0.1, 1 and 10 s were 1.36, 6.33 and 28.6 J respectively. The ED50 thresholds were correlated by a power law equation, ED50 = 6.31t (0.66) [J] where t is time [s], with correlation coefficient R = 0.9999. There exists a sufficient safety margin (factor of 28~60) between the human ED50 thresholds derived from the rabbit and the maximum permissible exposure (MPE) values in the current laser safety standards.