Real-time calibrating polarization-sensitive diffuse reflectance handheld probe characterizes clinically relevant anatomical locations of oral tissue in vivo
Author(s) -
Jianfeng Wang
Publication year - 2021
Publication title -
biomedical optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.362
H-Index - 86
ISSN - 2156-7085
DOI - 10.1364/boe.443652
Subject(s) - diffuse optical imaging , diffuse reflection , diffuse reflectance infrared fourier transform , optics , reflectivity , mobile device , in vivo , biomedical engineering , materials science , computer science , medicine , tomography , chemistry , physics , biology , microbiology and biotechnology , biochemistry , photocatalysis , operating system , catalysis
We report on the development of a unique real-time calibrating polarization-sensitive diffuse reflectance (rcPS-DR) handheld probe, and demonstrate its diagnostic potential through in-depth characterization and differentiation of clinically relevant anatomical locations of the oral cavity (i.e., alveolar process, lateral tongue and floor of mouth that account for 80% of all cases of oral squamous cell carcinoma) in vivo . With an embedded calibrating polytetrafluoroethylene (PTFE) optical diffuser, the PS-DR spectra bias arising from instrument response, time-dependent intensity fluctuation and fiber bending is calibrated through real-time measurement of the PS-DR system response function. A total of 554 in vivo rcPS-DR spectra were acquired from different oral tissue sites (alveolar process, n = 226, lateral tongue, n = 150 and floor of mouth, n = 178) of 14 normal subjects. Significantly ( P <0.05, unpaired 2-sided Student's t-test) different spectral ratio ( I 540 / I 575 ) representing oxygenated hemoglobin contents were found among the alveolar process, lateral tongue and floor of mouth. Further partial least squares discriminant analysis (PLS-DA) and leave-one-out, cross validation (LOOCV) show that, synergizing the complementary information of the two real-time calibrated orthogonal-polarized PS-DR spectra, the rcPS-DR technique is found to better differentiate alveolar process, lateral tongue, and the floor of mouth (accuracies of 88.2%, 83.9%, 84.4%, sensitivities of 80.5%, 75.8%, 78% and specificities of 93.5%, 87.7%, 86.8%) than standard DR (accuracies of 80.8%, 72.9%, 68.5%, sensitivities of 63.2%, 41.5%, 81.3% and specificities of 92.9%, 87.7%, 63.8%) without PS detection. This work showed the feasibility of the rcPS-DR probe as a tool for studying oral cavity lesions in real clinical applications.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom