z-logo
open-access-imgOpen Access
Dual-DMD hyperspectral spatial frequency domain imaging (SFDI) using dispersed broadband illumination with a demonstration of blood stain spectral monitoring
Author(s) -
Matthew B. Applegate,
Samuel S. Spink,
Darren Roblyer
Publication year - 2020
Publication title -
biomedical optics express
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.362
H-Index - 86
ISSN - 2156-7085
DOI - 10.1364/boe.411976
Subject(s) - optics , hyperspectral imaging , materials science , scattering , absorption (acoustics) , multispectral image , wavelength , monochromator , optoelectronics , physics , remote sensing , geology
Spatial frequency domain imaging (SFDI) is a widefield diffuse optical measurement technique capable of generating 2D maps of sub-surface absorption and scattering in biological tissue. We developed a new hyperspectral SFDI instrument capable of collecting images at wavelengths from the visible to the near infrared. The system utilizes a custom-built monochromator with a digital micromirror device (DMD) that can dynamically select illumination wavelength bands from a broadband quartz tungsten halogen lamp, and a second DMD to provide spatially modulated sample illumination. The system is capable of imaging 10 wavelength bands in approximately 25 seconds. The spectral resolution can be varied from 12 to 30 nm by tuning the input slit width and the output DMD column width. We compared the optical property extraction accuracy between the new device and a commercial SFDI system and found an average error of 23% in absorption and 6% in scattering. The system was highly stable, with less than 5% variation in absorption and less than 0.2% variation in scattering across all wavelengths over two hours. The system was used to monitor hyperspectral changes in the optical absorption and reduced scattering spectra of blood exposed to air over 24 hours. This served as a general demonstration of the utility of this system, and points to a potential application for blood stain age estimation. We noted significant changes in both absorption and reduced scattering spectra over multiple discrete stages of aging. To our knowledge, these are the first measurement of changes in scattering of blood stains. This hyperspectral SFDI system holds promise for a multitude of applications in quantitative tissue and diffuse sample imaging.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here