z-logo
open-access-imgOpen Access
The validation of a commercial enzyme-linked immunosorbent assay and the effect of freeze-thaw cycles of serum on the stability of cortisol and testosterone concentrations in Aceh cattle
Author(s) -
Gholib Gholib,
Sri Wahyuni,
Muslim Akmal,
Muhammad Hasan,
Muhammad Agil,
Bambang Purwantara
Publication year - 2020
Publication title -
f1000research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.099
H-Index - 60
ISSN - 2046-1402
DOI - 10.12688/f1000research.19804.2
Subject(s) - testosterone (patch) , zoology , biology , endocrinology , physiology
Background: To obtain accurate measurements of cortisol (C) and testosterone (T) in Aceh cattle, commercial enzyme-linked immunosorbent assay (ELISA) kits need to be carefully validated. Moreover, repeated freeze-thaw cycles during the storage of the samples may affect the stability of the hormones in the serum. Here, the reliability of C and T concentration measurements in the serum of Aceh cattle, was tested using commercial C and T ELISA kits designed to measure human C and T concentrations. Further, the effect of repeated freeze-thaw cycles on the stability of C and T concentrations in the serum was evaluated. Methods: Commercial C (Cat. no. EIA-1887) and T (Cat. no. EIA-1559) ELISA kits from DRG Instruments GmbH were validated through an analytical validation test (i.e., parallelism, accuracy, and precision) and a biological validation test (for C: effect of transportation on the C excretion; for T: the concentrations of T between bulls and cows). To test the effects of freeze-thaw cycles, cattle serum was subjected to the following treatments: (i) remained frozen at -20 O C (control group); (ii) exposed to freeze-thaw cycles for two, four, six, and eight times (test groups).   Results: Parallelism, accuracy, and precision tests showed that both  C and T ELISA kits adequately measured C and T in the serum of Aceh cattle. Concentrations of C post-transportation were significantly higher than pre-transportation (p 0.05). Conclusions: Commercial C (EIA-1887) and T (EIA-1559) ELISA kits are reliable assays for measuring serum C and T, respectively, in Aceh cattle. Repeated freeze-thaw cycles significantly affected the stability of serum C, but did not for T.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom