z-logo
open-access-imgOpen Access
CT-based ventilation imaging in radiation oncology
Author(s) -
Yevgeniy Vinogradskiy
Publication year - 2019
Publication title -
bjr|open
Language(s) - English
Resource type - Journals
ISSN - 2513-9878
DOI - 10.1259/bjro.20180035
Subject(s) - medicine , ventilation (architecture) , radiology , lung cancer , radiation therapy , medical physics , clinical trial , radiation treatment planning , lung , retrospective cohort study , functional imaging , surgery , oncology , mechanical engineering , engineering
A form of lung function imaging is emerging that uses phase-resolved four-dimensional CT (4DCT or breath-hold CT) images along with image processing techniques to generate lung function maps that provide a surrogate of lung ventilation. CT-based ventilation (referred to as CT-ventilation) research has gained momentum in Radiation Oncology because many lung cancer patients undergo four-dimensional CT simulation as part of the standard treatment planning process. Therefore, generating CT-ventilation images provides functional information without burdening the patient with an extra imaging procedure. CT-ventilation has progressed from an image processing calculation methodology, to validation efforts, to retrospective demonstration of clinical utility in Radiation Oncology. In particular, CT-ventilation has been proposed for two main clinical applications: functional avoidance radiation therapy and thoracic dose–response assessment. The idea of functional avoidance radiation therapy is to preferentially spare functional portions of the lung (as measured by CT-ventilation) during radiation therapy with the hypothesis that reducing dose to functional portions of the lung will lead to reduced rates of radiation-related thoracic toxicity. The idea of imaging-based dose–response assessment is to evaluate pre- to post-treatment CT-ventilation-based imaging changes. The hypothesis is that early, imaging-change-based response can be an early predictor of subsequent thoracic toxicity. Based on the retrospective evidence, the clinical applications of CT-ventilation have progressed from the retrospective setting to on-going prospective clinical trials. This review will cover basic CT-ventilation calculation methodologies, validation efforts, presentation of clinical applications, summarize on-going clinical trials, review potential uncertainties and shortcomings of CT-ventilation, and discuss future directions of CT-ventilation research.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom