Subject(s) - medicine , port (circuit theory) , surgery , complication , catheter , thrombosis , prospective cohort study , retrospective cohort study , confidence interval , cohort , electrical engineering , engineering
Purpose: Retrospective studies suggest that it may be safe to extend the maintenance flushing interval of implanted ports from once every month, as recommended by the manufacturer, to once every 3 months, but no prospective cohort studies have been done specifically assessing the safety and feasibility of this intervention.Methods: This was a phase II study in oncologic patients who retained a functional port after completion of systemic chemotherapy. Patients enrolled in the study had their port flushed once every 3 months and were observed until completion of five scheduled flushes (one on enrollment and four additional flushes, one every 3 months) or development of any port-related complication, including infections, thrombosis, and occlusions. The primary end points were frequency of port-related complications and port failure requiring removal.Results: A total of 87 patients were enrolled in the study. The median follow-up time was 308 days, accounting for a total of 24,202 catheter-days. There were 10 port-related complications (11.49%; 95% CI, 4.85% to 18.14%). No infection or symptomatic thrombosis occurred. The mean time to port-related complication was 184 days. No patients developed port failure while on protocol, but on subsequent medical record review, four patients developed a complication that required port removal or port revision within 30 days of being removed from the trial (4.6%; 95% CI, 0.4% to 8.8%; 0.17/1,000 catheter-days).Conclusion: Extending the maintenance flushes of implanted ports in adult oncologic patients to once every 3 months is safe, effective, and likely to increase patient adherence and satisfaction while decreasing the associated cost.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom