z-logo
open-access-imgOpen Access
Ignoring instead of chasing after coagulation factor VII during warfarin management: an interrupted time series study
Author(s) -
Alma R. Oskarsdottir,
Brynja R. Guðmundsdóttir,
Hulda M. Jensdottir,
Björn Flygenring,
Ragnar Pálsson,
Páll T. Önundarson
Publication year - 2021
Publication title -
blood
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.515
H-Index - 465
eISSN - 1528-0020
pISSN - 0006-4971
DOI - 10.1182/blood.2020008698
Subject(s) - incidence (geometry) , warfarin , medicine , prothrombin time , anticoagulant , gastroenterology , surgery , atrial fibrillation , mathematics , geometry
During warfarin management, variability in prothrombin time-based international normalized ratio (PT-INR) is caused, in part, by clinically inconsequential fluctuations in factor VII (FVII). The new factor II and X (Fiix)-prothrombin time (Fiix-PT) and Fiix-normalized ratio (Fiix-NR), unlike PT-INR, are only affected by reduced FII and FX. We assessed the incidence of thromboembolism (TE) and major bleeding (MB) in all 2667 patients on maintenance-phase warfarin managed at our anticoagulation management service during 30 months; 12 months prior to and 18 months after replacing PT-INR monitoring with Fiix-NR monitoring. Months 13 to 18 were predefined as transitional months. Using 2-segmented regression, a breakpoint in the monthly incidence of TE became evident 6 months after test replacement, that was followed by a 56% reduction in incidence (from 2.82% to 1.23% per patient-year; P = .019). Three-segmented regression did not find any significant trend in TE incidence (slope, +0.03) prior to test replacement; however, during months 13 to 18 and 19 to 30, the incidence of TE decreased gradually (slope, −0.12; R2 = 0.20; P = .007). The incidence of MB (2.79% per patient-year) did not differ. Incidence comparison during the 12-month Fiix and PT periods confirmed a statistically significant reduction (55-62%) in TE. Fiix monitoring reduced testing, dose adjustments, and normalized ratio variability and prolonged testing intervals and time in range. We conclude that ignoring FVII during Fiix-NR monitoring in real-world practice stabilizes the anticoagulant effect of warfarin and associates with a major reduction in TEs without increasing bleeding.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom