z-logo
open-access-imgOpen Access
FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
Author(s) -
Andrea Stracciolini,
Laura C. Boucher,
Sarah Jackson,
Naomi Brown,
Danielle Magrini,
Maxwell McKee-Proctor,
Pierre A. d’Hemecourt,
Patricia B. Delzell
Publication year - 2020
Publication title -
orthopaedic journal of sports medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.329
H-Index - 35
ISSN - 2325-9671
DOI - 10.1177/2325967120s00185
Subject(s) - medicine , medial patellofemoral ligament , intra rater reliability , patella , intraclass correlation , patellar ligament , ultrasound , ligament , inter rater reliability , orthodontics , tendon , anatomy , radiology , patellar tendon , confidence interval , clinical psychology , rating scale , developmental psychology , psychology , psychometrics
Background The medial patellofemoral ligament (MPFL) is an important soft tissue constraint to preventing patellar dislocations in young athletes. The anatomy of the MPFL has been investigated in cadaveric studies and magnetic resonance studies. No studies to date have provided anatomical data of the MPFL on ultrasonography.Purpose To investigate the feasibility of musculoskeletal ultrasonography for the evaluation of the MPFL, and to determine interrater and intrarater reliability for MPFL ultrasound measures.Methods Ten control participants (20 knees) 20 to 50 years underwent ultrasonography performed by 3 researchers (musculoskeletal ultrasound radiologist, athletic trainer/biomechanist, primary care sports medicine physician) from 3 different institutions for interrater reliability testing. Intrarater reliability testing was performed at 2 separate institutions by 4 physicians, each performing the same knee ultrasound protocol on 20 knees in 10 study participants 2 to 3 weeks apart. In total, 180 images were created for interrater reliability, and 480 images for intrarater reliability. Examinations were performed with linear high-frequency transducers (10-18 MHz) with the participant in the supine position and the extremity flexed at 45°. Measurements included ligament length (long axis to ligament) from the patellar to the femoral attachment sites, ligament width (short axis to ligament) at the patellar attachment, and ligament thickness (long axis to ligament) midway between the patella and femur. Mean and SD were calculated for all measurements. Intraclass correlation coefficient (ICC) analysis was used to assess intrarater and interrater reliability. ICC values 0.75 indicated excellent reliability.Results The mean US value for MPFL length was 44.83mm (SD 6.68), mean thickness 2.66mm (SD 0.85), and mean width 11.76mm (SD 2.99). The overall ICC values for interrater reliability testing indicated fair to good reliability for length measures (0.7) and poor reliability for thickness (–0.1) and width (0.3; Table 1.1). Overall ICC values for intrarater reliability indicated fair to good reliability for length (0.5), excellent for thickness (0.9), and poor reliability for width (–0.3; Table 1.2).Conclusions Musculoskeletal ultrasonography is a feasible and reliable office-based method of measuring MPFL length and thickness. These quantitative measures set the groundwork for establishing normative anatomical measures of the MPFL in athletes and establish a protocol for testing and measuring the MPFL using musculoskeletal ultrasonography.[Table: see text][Table: see text]

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here