T2-PROPELLER Compared to T2-FRFSE for Image Quality and Lesion Detection at Prostate MRI
Author(s) -
Dorota Czyżewska,
Nikita Sushentsev,
Eryk Latoch,
Rhys Slough,
Tristan Barrett
Publication year - 2021
Publication title -
canadian association of radiologists journal
Language(s) - English
Resource type - Journals
eISSN - 1488-2361
pISSN - 0846-5371
DOI - 10.1177/08465371211030206
Subject(s) - medicine , propeller , image quality , magnetic resonance imaging , lesion , t2 weighted , prostate , radiology , nuclear medicine , surgery , artificial intelligence , image (mathematics) , computer science , cancer , marine engineering , engineering
Purpose: The primary objective was to compare T2-FRFSE and T2-PROPELLER sequences for image quality. The secondary objective was to compare the ability to detect prostate lesions at MRI in the presence and absence of motion artefact using the 2 sequences.Methods: 99 patients underwent 3 T MRI examination of the prostate, including T2-FRFSE and T2-PROPELLER sequences. All patients underwent prostate biopsy. Two independent readers rated overall image quality, presence of motion artefact, and blurring for both sequences using a 5-point Likert scale. Scores were compared for the whole group and for subgroups with and without significant motion artefact. Outcome for lesion detection at an MRI threshold of PI-RADS score ≥3 was compared between T2-FRFSE and T2-PROPELLER.Results: The overall image quality was not significantly different between T2-FRFSE and T2-PROPELLER sequences (3.74 vs. 3.93, p = 0.275). T2-PROPELLER recorded a lesser degree of motion artefact (score 4.53 vs. 3.78, p <0.0001), but demonstrated greater image blurring (score 3.29 vs. 3.73, p <0.001). However, in a subgroup of patients with significant motion artefact on T2-FRFSE, the T2-PROPELLER sequence demonstrated significantly higher image quality (3.46 vs. 2.49, p <0.001). T2-FRFSE and T2-PROPELLER showed comparable positive predictive values for lesion detection at 93.2% and 97.7%, respectively.Conclusions: T2-PROPELLER provides higher quality imaging in the presence of motion artefact, but T2-FRFSE is preferred in the absence of motion. T2-PROPELLER is therefore recommended as a secondary T2 sequence when imaging requires repeat acquisition due to motion artefact.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom