z-logo
open-access-imgOpen Access
Fluctuations of Steady-State Accommodation Is a Marker for Screening Spasm of Near Reflex
Author(s) -
Shrikant R. Bharadwaj,
Chandrika Ravisankar,
Saujanwita Roy,
PremNandhini Satgunam
Publication year - 2021
Publication title -
translational vision science and technology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.508
H-Index - 21
ISSN - 2164-2591
DOI - 10.1167/tvst.10.11.9
Subject(s) - refractive error , accommodation , vergence (optics) , standard deviation , receiver operating characteristic , ophthalmology , pupil , limits of agreement , mathematics , steady state (chemistry) , medicine , physics , optics , eye disease , nuclear medicine , statistics , chemistry
Purpose To determine the utility of root mean squared (RMS) deviations of steady-state accommodation as a noncycloplegic marker for spasm of near reflex (SNR) vis-à-vis regular refractive errors. Methods Binocular steady-state responses of accommodation, pupil, and vergence of 20 patients with accommodative spasm subtype of SNR (SNR-A; 9–23 years) and 91 with regular refractive errors (29 emmetropes, 41 myopes, 21 hyperopes; 19–38 years) was recorded in the uncorrected refractive error state for 120 seconds using a dynamic (50 frames per second), infrared photorefractor. Mean and RMS deviation of raw data was calculated for three 20-second-long epochs and their diagnostic utility was determined using standard ROC curves. Results RMS deviations of accommodation increased with mean refractive error in SNR-A (y = −0.23x + 0.38; r 2 = 0.69; P < 0.001) and regular refractive error (y = −0.02x + 0.10; r 2 = 0.14; P = 0.002) cohorts, albeit with steeper slope and higher y-intercept in the former rather than the latter cohort. RMS deviation of 0.19D reliably distinguished SNR-A from regular refractive errors with a sensitivity and specificity of 95.2% and 92.2%, respectively [mean (±1 SEM) area under ROC curve: 0.98 ± 0.01]. The sensitivity, specificity, and area under ROC curve for RMS deviations of pupil (66.7%, 80%, and 0.70 ± 0.09) and vergence (52.4%, 84.6%, and 0.68 ± 0.08) were smaller than accommodation. Conclusions RMS deviations of steady-state accommodation is a robust noncycloplegic marker for differentiating SNR-A from regular refractive errors. Pupil and vergence fluctuations have limited utility in this regard. Translational Relevance RMS deviations of accommodation may be easily obtained using commercial photorefractors, and the cut-off values reported herein may be implemented to identify SNR-A during refractive error screening.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom