z-logo
open-access-imgOpen Access
Unaltered Perception of Suprathreshold Contrast in Early Glaucoma Despite Sensitivity Loss
Author(s) -
Habiba A. Bham,
Simon D. Dewsbery,
Jonathan Denniss
Publication year - 2020
Publication title -
investigative ophthalmology and visual science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.935
H-Index - 218
eISSN - 1552-5783
pISSN - 0146-0404
DOI - 10.1167/iovs.61.8.23
Subject(s) - contrast (vision) , visual field , glaucoma , audiology , ophthalmology , eccentricity (behavior) , medicine , optometry , psychology , optics , physics , social psychology
Purpose Glaucoma raises contrast detection thresholds, but our natural visual environment is dominated by high contrast that may remain suprathreshold in early to moderate glaucoma. This study investigates the effect of glaucoma on the apparent contrast of visible stimuli. Methods Twenty participants with glaucoma with partial visual field defects (mean age, 72 ± 7 years) and 20 age‐similar healthy controls (mean age, 70 ± 7 years) took part. Contrast detection thresholds for Gabor stimuli (SD, 0.75°) of four spatial frequencies (0.5, 1.0, 2.0, and 4.0 c/deg) were first measured at 10° eccentricity, both within and outside of visual field defects for participants with glaucoma. Subsequently, the contrast of a central Gabor was matched to that of a peripheral Gabor with contrast fixed at two times or four times the detection threshold. Data were analyzed by linear mixed modelling. Results Compared with controls, detection thresholds for participants with glaucoma were raised by 0.05 ± 0.025 (Michelson units, ± SE; P = 0.12) and by 0.141 ± 0.026 ( P < 0.001) outside and within visual field defects, respectively. For reference stimuli at two times the detection contrast, matched contrast ratios (matched/reference contrast) were 0.16 ± 0.039 ( P < 0.001) higher outside compared with within visual field defects in participants with glaucoma. Matched contrast ratios within visual field defects were similar to controls (mean 0.033 ± 0.066 lower; P = 0.87). For reference stimuli at four times the detection contrast, matched contrast ratios were similar across all three groups ( P = 0.58). Spatial frequency had a minimal effect on matched contrast ratios. Conclusions Despite decreased contrast sensitivity, people with glaucoma perceive the contrast of visible suprathreshold stimuli similarly to healthy controls. These results suggest possible compensation for sensitivity loss in the visual system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom