z-logo
open-access-imgOpen Access
Tissue Doppler Imaging of the Diaphragm in Healthy Subjects and Critically Ill Patients
Author(s) -
Eleni Soilemezi,
Savvoula Savvidou,
Panagiota Sotiriou,
Dimitrios Smyrniotis,
Matthew Tsagourias,
Dimitrios Matamis
Publication year - 2020
Publication title -
american journal of respiratory and critical care medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 6.272
H-Index - 374
eISSN - 1535-4970
pISSN - 1073-449X
DOI - 10.1164/rccm.201912-2341oc
Subject(s) - medicine , diaphragmatic breathing , contraction (grammar) , doppler imaging , diaphragm (acoustics) , cardiology , nuclear medicine , anesthesia , blood pressure , pathology , diastole , physics , loudspeaker , acoustics , alternative medicine
Rationale: Tissue Doppler imaging (TDI) is an echocardiographic method that measures the velocity of moving tissue. Objectives: We applied this technique to the diaphragm to assess the velocity of diaphragmatic muscle motion during contraction and relaxation. Methods: In 20 healthy volunteers, diaphragmatic TDI was performed to assess the pattern of diaphragmatic motion velocity, measure its normal values, and determine the intra- and interobserver variability of measurements. In 116 consecutive ICU patients, diaphragmatic excursion, thickening, and TDI parameters of peak contraction velocity, peak relaxation velocity, velocity-time integral, and TDI-derived maximal relaxation rate were assessed during weaning. In a subgroup of 18 patients, transdiaphragmatic pressure (Pdi)-derived parameters (peak Pdi, pressure-time product, and diaphragmatic maximal relaxation rate) were recorded simultaneously with TDI. Measurements and Main Results: In terms of reproducibility, the intercorrelation coefficients were >0.89 for all TDI parameters ( P  < 0.001). Healthy volunteers and weaning success patients exhibited lower values for all TDI parameters compared with weaning failure patients, except for velocity-time integral, as follows: peak contraction velocity, 1.35 ± 0.34 versus 1.50 ± 0.59 versus 2.66 ± 2.14 cm/s ( P  < 0.001); peak relaxation velocity, 1.19 ± 0.39 versus 1.53 ± 0.73 versus 3.36 ± 2.40 cm/s ( P  < 0.001); and TDI-maximal relaxation rate, 3.64 ± 2.02 versus 10.25 ± 5.88 versus 29.47 ± 23.95 cm/s 2 ( P  < 0.001), respectively. Peak contraction velocity was strongly correlated with peak transdiaphragmatic pressure and pressure-time product, whereas Pdi-maximal relaxation rate was significantly correlated with TDI-maximal relaxation rate. Conclusions: Diaphragmatic tissue Doppler allows real-time assessment of the diaphragmatic tissue motion velocity. Diaphragmatic TDI-derived parameters differentiate patients who fail a weaning trial from those who succeed and correlate well with Pdi-derived parameters.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here