Dynamic parameters of blood and aqueous humor endogenous intoxication in case of experimental corneal mechanical nonpenetrative injury and its correction by сeratoxenoimplant
Author(s) -
M. Turchyn
Publication year - 2015
Publication title -
medična ì klìnìčna himiâ
Language(s) - English
Resource type - Journals
eISSN - 2414-9934
pISSN - 2410-681X
DOI - 10.11603/mcch.2410-681x.2015.v17.i3.5058
Subject(s) - endogeny , aqueous humor , medicine , chemistry , anesthesia , endocrinology , ophthalmology
The influence of corneal mechanical non-penetrative injury on indices of endogenous intoxication of blood and aqueous humor in rabbits and its correction by сeratoxenoimplant were studied. It was determined the decrease in the level of endogenous intoxication, as was indicated by decreased content of middle mass molecules blood and aqueous humor as a result of surgical application of сeratoxenoimplant. This demonstrates the feasibility of further clinical testing and possible prospects in wide use of сeratoxenoimplants in ophthalmic practice to reduce metabolic manifestations of the syndrome of endogenous intoxication.