Design, Testing Analysis of High Tension Increased Safety Motor for Hazardous areas
Author(s) -
Bhagirath Ahirwal,
Tapas Chatterjee
Publication year - 2015
Publication title -
telkomnika: indonesian journal of electrical engineering/telkomnika
Language(s) - English
Resource type - Journals
eISSN - 2460-7673
pISSN - 2302-4046
DOI - 10.11591/tijee.v15i2.1536
Subject(s) - hazardous waste , high tension , induction motor , automotive engineering , tension (geology) , environmental science , engineering , electrical engineering , waste management , materials science , voltage , composite material , metallurgy , ultimate tensile strength
The increased safety (Ex e) motors are designed for safe operation in the zone 1 and 2 hazardous areas. The present paper describes the significant design parameters and successful testing of Ex e high tension (HT) induction motor rated 970KW/6.6KV/18 pole/ 3Phase/ 50Hz as per IS/IEC 60079-7 standard. The comparison of some useful design parameters is also given between safe area motor and hazardous area motor in this paper. The Ex e high tension induction motor mentioned in this paper have been manufactured by Bharat Heavy Electricals Ltd. (BHEL), Bhopal, India during the project and main author was the project leader.