z-logo
open-access-imgOpen Access
The Optimization of Hybrid Air Ventilation System Combined with Silica Gel and Thermoelectric Using Monitoring Control
Author(s) -
Jirod Chaisan,
Somchai Maneewan,
Chantana Punlek
Publication year - 2018
Publication title -
international journal of power electronics and drive systems (ijpeds)
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.322
H-Index - 21
ISSN - 2088-8694
DOI - 10.11591/ijpeds.v9.i4.pp1624-1633
Subject(s) - ventilation (architecture) , humidity , environmental science , relative humidity , thermal comfort , indoor air quality , thermoelectric effect , room air distribution , airflow , automotive engineering , materials science , environmental engineering , meteorology , engineering , mechanical engineering , physics , thermodynamics
In this paper, the experimental is evaluated temperature, humidity and air pollution from CO 2 by monitoring control of hybrid air ventilation for producing fresh air. The experimental divided into 2 conditions: hybrid air ventilation on-off, recovery silica gel unit. That research consider of a voltage of thermoelectric devices relative with air cooling under thermal comfort zone Thailand climate conditions. In the experimental was designed by the DOAS system (dedicate outdoor air system) concept. Whereas, the hybrid air ventilation was improved by old air ventilation which the hybrid air ventilation combined with silica gel unit and thermoelectric device. Monitoring control is written by Arduino program that is open source for control performance of processes such as sensors, electric current and fan unit. That working is specified temperature and humidity Thailand thermal comfort range. In the part of CO 2 was released rate approximately 900 ppm corresponded with indoor air quality standard (IAQs). The results of experimental suggested that in case of hybrid air ventilation system explained thermal, humidity and CO 2 distribution due to the system was adapted significantly in the comfort zone temperature and humidity about 28 and 58% respectively. However, the CO 2 released into the hybrid air ventilation although control during 900 – 1,000 ppm. High CO 2 concentration in comfort zone used the hybrid air ventilation that decreased CO 2 inlet under ASHRAE 62.2. Therefore, the experimental is an evaluation of monitoring control hybrid air ventilation for management comfort zone. Finally this research concept of the optimization of the hybrid air ventilation combination with thermoelectric devices and silica gel unit.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here