z-logo
open-access-imgOpen Access
Low-Titer Group O Whole-Blood Resuscitation in the Prehospital Setting in Israel: Review of the First 2.5 Years’ Experience
Author(s) -
Levin Dan,
Zur Maoz,
Shinar Eilat,
Moshe Tzadok,
Tsur Avishai M.,
Nadler Roy,
Yazer Mark H.,
Epstein Danny,
Avital Guy,
Gelikas Shaul,
Glassberg Elon,
Benov Avi,
Chen Jacob
Publication year - 2021
Publication title -
transfusion medicine and hemotherapy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.971
H-Index - 39
eISSN - 1660-3818
pISSN - 1660-3796
DOI - 10.1159/000519623
Subject(s) - review article
The Israeli Defense Forces Medical Corps (IDF-MC) implemented the use of low-titer group O whole blood (LTOWB) as the first-choice resuscitation fluid in the IDF airborne Combat Search and Rescue Unit (IDF-CSAR) for aerial evacuation of both military and civilian casualties in June 2018 for injured patients with hemorrhagic shock and at least one of the following: systolic blood pressure <90 mm Hg, heart rate >130 beats/min, deterioration of consciousness without head injury or hemoglobin concentration ≤7 g/dL. Method: All casualties treated with LTOWB by IDF-CSAR providers from June 2018 to January 2021 were included. Demographic and prehospital treatment data were collected in order to check compliance and adherence to the IDF-MC guidelines. This is a follow-up retrospective report. Results: Overall, 1,608 LTOWB units were supplied to the IDF-CSAR during the study period. Of these, 33 were transfused to 27 casualties; 17 (69%) with blunt injury, 8 (29.6%) with penetrating injuries, and 1 (3.7%) with gastrointestinal bleeding without trauma. The leading cause of injury was motor vehicle accidents. A total of 23 casualties received 1 unit of LTOWB, 3 received 2 units and 1 patient received 4 units. Two casualties were children. The median heart rate was 120 beats/min, 8 (29.6%) casualties had heart rates >130 beats/min. Median systolic blood pressure was 95 mm Hg, 7 (26%) casualties had blood pressure <90 mm Hg. The median Glasgow Coma Score was 14. No adverse reactions were documented following the administration of LTOWB. 77.8% of patients received LTOWB in adherence to the guidelines. Conclusion: Appropriate administration of LTOWB has improved over time in IDF-CSAR. Using LTOWB is feasible and simpler than administering packed red blood cells and plasma concurrently. Further efforts are needed to introduce LTOWB in other prehospital and in-hospital scenarios, with an increase in the maximum antibody titer threshold, to meet the expected increase in demand.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here