z-logo
open-access-imgOpen Access
Health Preference Measures in Patients with Obstructive Sleep Apnea Syndrome Undergoing Continuous Positive Airway Pressure Therapy: Data from a Randomized Trial
Author(s) -
Fabian Huber,
Michaël Furian,
Malcolm Kohler,
Tsogyal D. Latshang,
Yvonne Nussbaumer-Ochsner,
Alexander Turk,
Otto D. Schoch,
I Laube,
Robert Thurnheer,
Konrad E. Bloch
Publication year - 2021
Publication title -
respiration
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.264
H-Index - 81
eISSN - 1423-0356
pISSN - 0025-7931
DOI - 10.1159/000513306
Subject(s) - medicine , epworth sleepiness scale , continuous positive airway pressure , obstructive sleep apnea , confidence interval , randomized controlled trial , apnea–hypopnea index , physical therapy , sleep apnea , positive airway pressure , health utilities index , polysomnography , apnea , anesthesia , health related quality of life , disease
Background: In patients with obstructive sleep apnea syndrome (OSAS), the preference-based, health-related quality of life in terms of utility has not been extensively studied. Objective: To address this point, we compared the performance of different instruments assessing utility in patients with OSAS undergoing continuous positive airway pressure (CPAP) therapy. Materials and Methods: Data of 208 patients with OSAS (28 women, mean ± SE age 54.4 ± 0.7 years, apnea-hypopnea index (AHI) 51.9 ± 1.8/h, Epworth sleepiness score 13.4 ± 0.2) participating in a randomized trial of different CPAP modalities over 2 years were analyzed. Evaluations included sleep studies, Epworth sleepiness scale, and several utility instruments that measure subjective health preference on a scale ranging from 1 (most preferred and perfect health) to 0 (least preferred and very poor health). Results: After 2 years of CPAP therapy, the mean ± SE AHI was 6.7 ± 1.5/h and Epworth score 7.9 ± 0.4, both p < 0.001 versus baseline. Baseline utilities and changes (95% confidence interval) after 2 years of CPAP therapy were EuroQol 5-dimensions 0.79 ± 0.01, 0.02 (0.00–0.05, p = 0.064); short-form 6-dimension medical outcome questionnaire 0.72 ± 0.01, 0.06 (0.04–0.08, p < 0.001); Euro-thermometer visual analog scale 0.70 ± 0.01, 0.09 (0.07–0.12, p < 0.001); time trade-off 0.82 ± 0.01, 0.03 (0.01–0.06, p = 0.002); and standard gamble 0.82 ± 0.01, −0.01 (−0.03 to 0.02, p = 0.712). Conclusion: The short-form 6-dimensions questionnaire, the Euro-thermometer, and the time trade-off instruments reflected the major clinical improvements in OSAS, while the EuroQoL 5-dimensions and standard gamble tests were not sensitive to CPAP effects. These results indicate that the evaluation of utility of a treatment for OSAS depends critically on the instrument used, which is important from an individual and societal perspective.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here