Low Tidal Volume Positive End-Expiratory Pressure versus High Tidal Volume Zero-Positive End-Expiratory Pressure and Postoperative Pulmonary Functions in Robot-Assisted Laparoscopic Radical Prostatectomy
Author(s) -
Haliloglu Murat,
Bilgili Beliz,
Ozdemir Mehtap,
Umuroglu Tumay,
Bakan Nurten
Publication year - 2017
Publication title -
medical principles and practice
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.426
H-Index - 45
eISSN - 1423-0151
pISSN - 1011-7571
DOI - 10.1159/000484693
Subject(s) - original paper
Objective: The aim was to compare the effects of low tidal volume (VT) and moderate positive end-expiratory pressure (PEEP) with high VT and zero end-expiratory pressure (ZEEP) on postoperative pulmonary functions and oxygenation in patients undergoing robot-assisted laparoscopic radical prostatectomy. Subjects and Methods: Forty-four patients were randomized into low VT-PEEP and high VT-ZEEP groups. The patients were ventilated with a VT of 6 mL/kg and 8 cm H2O PEEP in the low VT-PEEP group and a VT of 10 mL/kg and 0 cm H2O PEEP in the high VT-ZEEP group. Preoperative and postoperative spirometric measurements were done and chest X-rays were evaluated using the radiological atelectasis score (RAS). p < 0.05 was considered statistically signicant. Results: The intraoperative and postoperative arterial partial pressure of oxygen and arterial oxygen saturation values were significantly higher in the low VT-PEEP group than in the high VT-ZEEP group. At all times, the arterial-to-alveolar oxygenation gradients were significantly lower in the low VT-PEEP group than in the high VT-ZEEP group. Preoperative RAS were similar in both groups, but the postoperative RAS was significantly lower in the low VT-PEEP group ( p < 0.001). Forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow rate recorded postoperatively were significantly lower in the high VT-ZEEP group ( p < 0.001). Conclusions: Postoperative pulmonary functions were less impaired in patients ventilated with a VT of 6 mL/kg and 8 cm H2O PEEP than in patients ventilated with a VT of 10 mL/kg and ZEEP.