z-logo
open-access-imgOpen Access
Safety Outcomes Using a Proximal Protection Device in Carotid Stenting of Long Carotid Stenoses
Author(s) -
Kunakorn Atchaneeyasakul,
Priyank Khandelwal,
Sudheer Ambekar,
Kevin Ramdas,
Luis Guada,
Dileep R. Yavagal
Publication year - 2016
Publication title -
interventional neurology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.07
H-Index - 5
eISSN - 1664-9737
pISSN - 1664-5545
DOI - 10.1159/000447022
Subject(s) - medicine , stenosis , asymptomatic , stroke (engine) , carotid stenting , stent , perioperative , cardiology , lesion , target lesion , carotid arteries , surgery , radiology , myocardial infarction , carotid endarterectomy , percutaneous coronary intervention , mechanical engineering , engineering
Background: Embolic protection devices can prevent atherosclerotic emboli during carotid stenting. Newer proximal protection devices reverse flow in the internal carotid artery (ICA), leading to reduction in perioperative microemboli. The risk of stroke is high for carotid stenting of ICA lesions with a length >10 mm and/or angiographic string sign. Objective: We aimed to evaluate the safety outcomes of proximal embolic protection device usage in this high-risk group. Methods: This is a retrospective analysis of patients who underwent carotid stenting procedures with proximal embolic protection devices at a tertiary care center. High-risk features for adverse events with carotid stenting were identified. Peri- and postprocedural outcomes were recorded. We further compared outcomes in patients with a carotid stenosis length >10 mm to those with shorter stenosis. Results: From January 2011 to December 2014, we included 27 patients; 96.3% were symptomatic and 3.7% were asymptomatic. There was a stent placement technical success rate of 100%. No major stroke or coronary events were recorded. One minor stroke event developed in one patient. A carotid lesion length >10 mm and/or angiographic string sign was noted in 21/27 patients, with an average lesion length of 14.4 mm. One patient (4.8%) in this group developed a minor stroke event. Neither a coronary nor a major stroke event was recorded in this group. There was no significant difference in the complication rate between the long lesion and the control group. Conclusion: In our patient cohort, it was found that a proximal embolic protection device is safe for patients with carotid stenosis, including those with a carotid lesion length >10 mm and/or angiographic string sign.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here