Wavelet Transform Image Enhancement Algorithm-Based Evaluation of Lung Recruitment Effect and Nursing of Acute Respiratory Distress Syndrome by Ultrasound Image
Author(s) -
Wangyan Jin,
Ling Dai,
Liuyan Ge,
Xu-hua Huang,
Guanhua Xu,
Chunhong Qu,
Jianfei Sun
Publication year - 2021
Publication title -
journal of healthcare engineering
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.509
H-Index - 29
eISSN - 2040-2309
pISSN - 2040-2295
DOI - 10.1155/2021/8960465
Subject(s) - ards , medicine , ultrasound , lung ultrasound , algorithm , peak signal to noise ratio , lung , anesthesia , cardiology , image (mathematics) , radiology , mathematics , computer science , artificial intelligence
This study aimed to analyze the application of ultrasound images of lung recruitment (LR) nursing treatment guided by positive-end expiratory pressure (PEEP) in patients with acute respiratory distress syndrome (ARDS). An ultrasound image enhancement algorithm (UIEA) wavelet transform (WT) was constructed, and the soft threshold (ST) and adjacent region average (ARA) were introduced for simulation comparison. In addition, the signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), and running time were undertaken as the evaluation indexes. The WT algorithm was applied to the ultrasound images of 85 ARDS patients before and after PEEP recruitment. The mean artery pressure (MAP), heart rate (HR), and central venous pressure (CVP), peak inspiratory pressure (Ppeak), mean inspiratory pressure (Pmean), dynamic lung compliance (DLC), PCO 2 , and PaO 2 /FiO 2 of the patients were recorded before and after the LR. The results showed that the signal-to-noise ratio (SNR) (19.67 ± 3.15 dB) and PSNR (23.08 ± 2.08 dB) of the images enhanced by the WT algorithm were much higher than those of ST (13.88 ± 2.74 dB and 14.62 ± 1.76 dB, respectively) and ARA (14.96 ± 3.06 dB and 15.11 ± 1.94 dB, respectively), while the running time was in adverse ( P < 0.05); the HR and CVP of patients after LR nursing treatment were increased greatly, while the MAP was in the opposite case ( P < 0.05); after LR nursing treatment, Ppeak, Pmean, DLC, PCO 2 , and PaO 2 /FiO 2 of the patient were significantly greater than those before the LR, and the difference was statistically significant ( P < 0.05). In short, the WT algorithm not only enhanced the quality of ultrasound images but also shortened the running time and improved the processing efficiency. PEEP LR nursing treatment could effectively improve the vascular patency, cardiac ejection capacity, and DLC in patients with ARDS, thereby increasing the airway pressure and maintaining the unobstructed expiration.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom