Effect of compliance and hematocrit on wall shear stress in a model of the entire coronary arterial tree
Author(s) -
Yunlong Huo,
Ghassan S. Kassab
Publication year - 2009
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.91013.2008
Subject(s) - hematocrit , cardiology , compliance (psychology) , hemodynamics , shear stress , medicine , coronary arteries , coronary vessel , blood viscosity , arterial tree , perfusion , coronary circulation , blood flow , blood pressure , materials science , artery , psychology , social psychology , composite material
A hemodynamic analysis is implemented in the entire coronary arterial tree of diastolically arrested, vasodilated pig heart that takes into account vessel compliance and blood viscosity in each vessel of a large-scale simulation involving millions of vessels. The feed hematocrit (Hct) is varied at the inlet of the coronary arterial tree, and the Fahraeus-Lindqvist effect and phase separation are considered throughout the vasculature. The major findings are as follows: 1) vessel compliance is the major determinant of nonlinearity of the pressure-flow relation, and 2) changes in Hct influence wall shear stress (WSS) in epicardial coronary arteries more significantly than in transmural and perfusion arterioles because of the Fahraeus-Lindqvist effect. The present study predicts the flow rate as a second-order polynomial function of inlet pressure due to vessel compliance. WSS in epicardial coronary arteries increases >15% with an increase of feed Hct from 45% to 60% and decreases >15% with a decrease of feed Hct from 45% to 30%, whereas WSS in small arterioles is not affected as feed Hct changes in this range. These findings have important implications for acute Hct changes under vasodilated conditions.