z-logo
open-access-imgOpen Access
Hyperthermia reduces electromechanical delay via accelerated electrochemical processes
Author(s) -
Adèle Mornas,
Sébastien Racinais,
Franck Brocherie,
Marine Alhammoud,
Robin Hager,
Yanis Desmedt,
Gaël Guilhem
Publication year - 2020
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.00538.2020
Subject(s) - hyperthermia , materials science , chemistry , medicine
The present study aimed to determine the effect of hyperthermia on both electrochemical and mechanical components of the electromechanical delay (EMD), using very-high-frame-rate ultrasound. Electrically evoked peak twitch force, EMD, electrochemical (D m ; i.e., delay between stimulation and muscle fascicle motion), and mechanical (T m ; i.e., delay between fascicle motion and force production onset) components of EMD were assessed in 16 participants. Assessments were conducted in a control ambient environment (CON; 26°C, 34% relative humidity) and in a hot ambient environment (HOT; 46-50°C, 18% relative humidity, after ∼127 min of heat exposure). Following heat exposure, gastrocnemius medialis emperature was 37.0 ± 0.6°C in HOT vs. 34.0 ± 0.8°C in CON ( P < 0.001). EMD was shorter (9.4 ± 0.8 ms) in HOT than in CON (10.8 ± 0.6 ms, P < 0.001). Electrochemical processes were shorter in HOT than in CON (4.0 ± 0.8 ms vs. 5.5 ± 0.9 ms, respectively, P < 0.001), whereas mechanical processes were unchanged ( P = 0.622). These results demonstrate that hyperthermia reduces electromechanical delay via accelerated electrochemical processes, whereas force transmission along the active and passive parts of the series elastic component is not affected following heat exposure. The present study demonstrates that heat exposure accelerates muscle contraction thanks to faster electrochemical processes. Further investigations during voluntary contractions would contribute to better understand how these findings translate into motor performance. NEW & NOTEWORTHY Hyperthermia (targeted core temperature: 38.5°C) reduces the time between gastrocnemius medialis stimulation and the onset of plantar flexor force production in vivo. This reduction in electromechanical delay is concomitant to an earlier motion of muscle fascicle compared with thermoneutral environment. However, hyperthermia has no impact on the duration of force transmission along aponeurosis and tendon, thereby reflecting different effects of heat exposure on contractile and elastic properties of the muscle-tendon unit.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom