z-logo
open-access-imgOpen Access
Multiple coupled resonances in the human vascular tree: refining the Westerhof model of the arterial system
Author(s) -
G. Schumacher,
Jens J. Kaden,
Frederik Trinkmann
Publication year - 2018
Publication title -
journal of applied physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.253
H-Index - 229
eISSN - 8750-7587
pISSN - 1522-1601
DOI - 10.1152/japplphysiol.00405.2017
Subject(s) - arterial tree , waveform , transfer function , aortic pressure , pulse (music) , blood pressure , computer science , coupling (piping) , reflection (computer programming) , software , pulse pressure , function (biology) , aorta , tree (set theory) , biomedical engineering , cardiology , engineering , mathematics , medicine , telecommunications , mechanical engineering , electrical engineering , mathematical analysis , radar , evolutionary biology , detector , biology , programming language
The human arterial vascular tree can be described by multicompartment models using electrical components. First introduced in the 1960s by Noordergraaf and Westerhof, these hardware-based approaches required several simplifications. We were able to remove the restrictions using modern software simulation tools and improve overall model quality considerably. Whereas the original Westerhof model consisted of 121 Windkessel elements, the refined model has 711 elements and gives realistic pulse waveforms of the aorta and brachial and radial arteries with realistic blood pressures. Moreover, novel insights concerning the formation of the physiological aortic-to-radial transfer function were gained. Its being potentially due to the coupling of many small resonant elements gives new impetus to the discussion of arterial pressure wave reflection. The individualized transfer function derived from our improved model incorporates distinct patient characteristics and can potentially be used for estimation of central blood pressure values. NEW & NOTEWORTHY We were able to find an individualized transfer function giving realistic pulse waveforms and blood pressures using a multicompartment model of the arterial system. Based on the hardware-built Westerhof approach, several simplifications initially introduced in the 1960s could be reversed using software simulation. Overall model quality was improved considerably, and multiple coupled resonances were identified as potential explanation for the formation of the aortic-to-radial transfer function, giving new impetus to the discussion of arterial pressure wave reflection.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here