z-logo
open-access-imgOpen Access
His bundle pacing shows similar ventricular electrical activation as sinus: selective and nonselective His pacing indistinguishable
Author(s) -
Annie Hirahara,
Matthias Lange,
Ankur Shah,
Muhammad S. Khan,
Ravi Ranjan,
Greg Stoddard,
Derek J. Dosdall
Publication year - 2021
Publication title -
american journal of physiology. heart and circulatory physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.524
H-Index - 197
eISSN - 1522-1539
pISSN - 0363-6135
DOI - 10.1152/ajpheart.00292.2020
Subject(s) - bundle , cardiology , medicine , ventricular pacing , materials science , heart failure , composite material
His bundle pacing utilizes the His-Purkinje system to produce more physiological activation compared with traditional pacing therapies, but differences in electrical activation between pacing techniques are not yet quantified in terms of activation pattern. Furthermore, clinicians distinguish between selective and nonselective His pacing, but measurable differences in electrical activation remain to be seen. Hearts isolated from seven dogs were perfused using the Langendorff method. Electrograms were recorded using two 64-electrode basket catheters in the ventricles and a 128-electrode sock situated around the ventricles during sinus rhythm (right atrial pacing), right ventricular (RV) pacing, biventricular cardiac resynchronization therapy (biV-CRT), selective His pacing (selective capture of the His bundle), and nonselective His pacing (capture of nearby myocardium and His bundle). Activation maps were generated from these electrograms. Total activation time (TAT) was measured from the activation maps, and QRS duration was measured from a one-lead pseudo-ECG. Results showed that TAT, QRS duration, and activation sequence were most similar between sinus, selective, and nonselective His pacing. Bland-Altman analyses showed highest levels of similarity between all combinations of sinus, selective, and nonselective His pacing. RV and biV-CRT activation patterns were distinct from sinus and had significantly longer TAT and QRS duration. Cumulative activation graphs were most similar between sinus, selective, and nonselective His pacing. In conclusion, selective pacing and nonselective His bundle pacing are more similar to sinus compared with RV and biV-CRT pacing. Furthermore, selective pacing and nonselective His bundle pacing are not significantly different electrically. NEW & NOTEWORTHY Our high-density epicardial and endocardial electrical mapping study demonstrated that selective pacing and nonselective His bundle pacing are more electrically similar to sinus rhythm compared with right ventricular and biventricular cardiac resynchronization therapy pacing. Furthermore, small differences between selective and nonselective His bundle pacing, specifically a wider QRS in nonselective His pacing, do not translate into significant differences in the global activation pattern.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here