Endpoint Quaking-Induced Conversion: a Sensitive, Specific, and High-Throughput Method for Antemortem Diagnosis of Creutzfeldt-Jacob Disease
Author(s) -
Keding Cheng,
Robert Vendramelli,
Angela Sloan,
Brooks Waitt,
Lisa Podhorodecki,
Debra Godal,
J. David Knox
Publication year - 2016
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.00542-16
Subject(s) - recombinant dna , cerebrospinal fluid , fluorescence , virology , prion protein , medicine , pathology , biology , disease , biochemistry , physics , gene , quantum mechanics
The Prion Laboratory Section of the Public Health Agency of Canada supports heath care professionals dealing with patients suspected to have Creutzfeldt-Jakob disease (CJD) by testing cerebrospinal fluid (CSF) for protein markers of CJD. To better serve Canadian diagnostic requirements, a quaking-induced conversion (QuIC)-based assay has been added to the test panel. The QuIC tests exploit the ability of disease-associated prion protein, found in the CSF of a majority of CJD patients, to convert a recombinant prion protein (rPrP) into detectable amounts of a misfolded, aggregated form of rPrP. The rPrP aggregates interact with a specific dye, causing a measurable change in the dye's fluorescence emission spectrum. Optimal test and analysis parameters were empirically determined. Taking both practical and performance considerations into account, an endpoint QuIC (EP-QuIC) configuration was chosen. EP-QuIC uses a thermo-mixer to perform the shaking necessary to produce the quaking-induced conversions. Fluorescence readings are obtained from a microwell fluorescence reader only at the beginning and the end of EP-QuIC reactions. Samples for which the relative fluorescence unit ratio between the initial and final readings represent a ≥4 increase in signal intensity in at least two of the three replicates are classified as positive. A retrospective analysis of 91 CSF samples that included 45 confirmed cases of CJD and 46 non-CJD cases was used to estimate the performance characteristics of the EP-QuIC assay. The diagnostic sensitivity and specificity of the EP-QuIC test of this set of samples were 98 and 91%, respectively.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom