z-logo
open-access-imgOpen Access
A Simple Phosphate-Buffered-Saline-Based Extraction Method Improves Specificity of HIV Viral Load Monitoring Using Dried Blood Spots
Author(s) -
Tariro Makadzange,
Kathryn Boyd,
Benjamin Chimukangara,
Collen Masimirembwa,
David Katzenstein,
Chiratidzo E. Ndhlovu
Publication year - 2017
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.00176-17
Subject(s) - viral load , chromatography , spots , human immunodeficiency virus (hiv) , dried blood , phosphate buffered saline , extraction (chemistry) , dried blood spot , virology , phosphate , chemistry , biology , medicine , pathology , biochemistry
Although Roche COBAS Ampliprep/COBAS TaqMan (CAP/CTM) systems are widely used in sub-Saharan Africa for early infant diagnosis of HIV from dried blood spots (DBS), viral load monitoring with this system is not practical due to nonspecific extraction of both cell-free and cell-associated viral nucleic acids. A simplified DBS extraction technique for cell-free virus elution using phosphate-buffered saline (PBS) may provide an alternative analyte for lower-cost quantitative HIV virus load (VL) testing to monitor antiretroviral therapy (ART). We evaluated the CAP/CTM v2.0 assay in 272 paired plasma and DBS specimens using the cell-free virus elution method and determined the level of agreement, sensitivity, and specificity at thresholds of target not detected (TND), target below the limit of quantification (BLQ) (<20 copies/ml in plasma or <400 copies/ml in DBS), and VL of <1,000 copies/ml, and VL of <5,000 copies/ml. Reported plasma VL ranged from TND, or <20, to 5,781,592 copies/ml, and DBS VL ranged from TND, or <400, to 467,600 copies/ml. At <1000 copies/ml, agreement between DBS and plasma was 96.7% (kappa coefficient, 0.93; P < 0.0001). The mean difference between DBS and plasma VL values was -1.06 log 10 copies/ml (95% confidence interval [CI], -1.17, -0.97; P < 0.0001). At a treatment failure threshold of >1,000 copies/ml, the sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) were 92.7%, 100%, 100%, and 94.3%, respectively. PBS elution of DBS offers a sensitive and specific method for monitoring plasma viremia among adults and children on ART at the WHO-recommended threshold of >1,000 copies/ml on the Roche CAP/CTM system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom