z-logo
open-access-imgOpen Access
Use of Highly Encapsulated Streptococcus pneumoniae Strains in a Flow-Cytometric Assay for Assessment of the Phagocytic Capacity of Serotype-Specific Antibodies
Author(s) -
Wim Jansen,
Jan Gootjes,
M. R. Zelle,
Dace V. Madore,
J. Verhoef,
H. Snippe,
A F Verheul
Publication year - 1998
Publication title -
clinical and diagnostic laboratory immunology
Language(s) - English
Resource type - Journals
eISSN - 1098-6588
pISSN - 1071-412X
DOI - 10.1128/cdli.5.5.703-710.1998
Subject(s) - phagocytosis , streptococcus pneumoniae , serotype , microbiology and biotechnology , antiserum , antibody , biology , flow cytometry , antibody opsonization , bacterial capsule , titer , immunology , opsonin , virulence , biochemistry , gene , antibiotics
A phagocytosis assay for Streptococcus pneumoniae based on flow cytometry (FACS) with human polymorphonuclear cells and human complement was developed for the study of human vaccination antisera. Human prevaccination sera already contain high levels of C-polysaccharide (C-PS) antibodies, which are not protective in humans but which might give false positive results in a flow-cytometry-based assay. Cultures of S. pneumoniae grown to log phase on three consecutive days, followed by heat inactivation, yielded stable and highly encapsulated strains for serotypes 6A, 6B, 14, 19F, and 23F. As a result, only serotype-specific antibodies were able to facilitate phagocytosis of these strains, whereas no phagocytosis was observed with antibodies against C-PS or pneumococcal surface proteins. No, or weak, phagocytosis was observed with human prevaccination sera, whereas in general, postvaccination antisera facilitated phagocytosis. A highly significant correlation was observed between enzyme-linked immunosorbent assay titers and FACS phagocytosis titers (r = 0.98, P < 0.001) for serotype 23F pneumococci with human vaccination antisera. For all serotypes, interassay variation was below 10%. Major advantages of this assay over the classical killing assay are that (i) limited amounts of sera are required (10 microliter per titration curve), (ii) 600 samples can be processed in one day by one person, and (iii) cells can be fixed and measurement of the samples can be performed up to 1 week later.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom