z-logo
open-access-imgOpen Access
Effect of bladder filling on doses to prostate and organs at risk: a treatment planning study
Author(s) -
Moiseenko Vitali,
Liu Mitchell,
Kristensen Sarah,
Gelowitz Gerald,
Berthelet Eric
Publication year - 2007
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1120/jacmp.v8i1.2286
Subject(s) - rectum , prostate , medicine , radiation therapy , urinary bladder , nuclear medicine , urology , prostate cancer , radiation treatment planning , radiology , surgery , cancer
In the present study, we aimed to evaluate effects of bladder filling on dose–volume distributions for bladder, rectum, planning target volume (PTV), and prostate in radiation therapy of prostate cancer. Patients ( n = 21 ) were scanned with a full bladder, and after 1 hour, having been allowed to void, with an empty bladder. Radiotherapy plans were generated using a four‐field box technique and dose of 70 Gy in 35 fractions. First, plans obtained for full‐ and empty‐bladder scans were compared. Second, situations in which a patient was planned on full bladder but was treated on empty bladder, and vice versa, were simulated, assuming that patients were aligned to external tattoos. Doses to the prostate [equivalent uniform dose (EUD)], bladder and rectum [effective dose ( D eff ) ], and normal tissue complication probability (NTCP) were compared. Dose to the small bowel was examined. Mean bladder volume was 354.3 cm 3 when full and 118.2 cm 3 when empty. Median prostate EUD was 70 Gy for plans based on full‐ and empty‐bladder scans alike. The median rectalD effwas 55.6 Gy for full‐bladder anatomy and 56.8 Gy for empty‐bladder anatomy, and the corresponding bladderD effwas 29.0 Gy and 49.3 Gy respectively. In 1 patient, part of the small bowel (7.5 cm 3 ) received more than 50 Gy with full‐bladder anatomy, and in 6 patients, part ( 2.5   cm 3 − 30   cm 3 ) received more than 50 Gy with empty‐bladder anatomy. Bladder filling had no significant impact on prostate EUD or rectalD eff. A minimal volume of the small bowel received more than 50 Gy in both groups, which is below dose tolerance. The bladderD effwas higher with empty‐bladder anatomy; however, the predicted complication rates were clinically insignificant. When the multileaf collimator pattern was applied in reverse, substantial underdosing of the planning target volume (PTV) was observed, particularly for patients with prostate shifts in excess of 0.5 cm in any one direction. However, the prostate shifts showed no correlation with bladder filling, and therefore the PTV underdosing also cannot be related to bladder filling. For some patients, bladder dose–volume constraints were not fulfilled in the worst‐case scenario—that is, when a patient planned with full bladder consistently arrived for treatment with an empty bladder. PACS numbers: 87.53.‐j, 87.53.Kn, 87.53.Tf

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here