Evaluation of kidney motion and target localization in abdominal SBRT patients
Author(s) -
Sonier Marcus,
Chu William,
Lalani Nafisha,
Erler Darby,
Cheung Patrick,
Korol Renee
Publication year - 2016
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1120/jacmp.v17i6.6406
Subject(s) - nuclear medicine , medicine , cone beam computed tomography , radiation treatment planning , image guided radiation therapy , radiation therapy , computed tomography , radiology
The purpose of this study was to evaluate bilateral kidney and target translational/rotational intrafraction motion during stereotactic body radiation therapy treatment delivery of primary renal cell carcinoma and oligometastatic adrenal lesions for patients immobilized in the Elekta BodyFIX system. Bilateral kidney motion was assessed at midplane for 30 patients immobilized in a full‐body dual‐vacuum‐cushion system with two patients immobilized via abdominal compression. Intrafraction motion was assessed for 15 patients using kilovoltage cone‐beam computed tomography (kV‐CBCT) datasets ( n = 151 ) correlated to the planning CT. Patient positioning was corrected for translational and rotational misalignments using a robotic couch in six degrees of freedom if setup errors exceeded 1 mm and 1°. Absolute bilateral kidney motion between inhale and exhale 4D CT imaging phases for left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions was 1.51 ± 1.00 mm , 8.10 ± 4.33 mm , and 3.08 ± 2.11 mm , respectively. Residual setup error determined across CBCT type (pretreatment, intrafraction, and post‐treatment) for x (LR), y (SI), and z (AP) translations was 0.63 ± 0.74 mm , 1.08 ± 1.38 mm , and 0.70 ± 1.00 mm ; while for x (pitch), y (roll), and z (yaw) rotations was 0.24 ± 0.39 ° , 0.19 ± 0.34 ° , and 0.26 ± 0.43 ° , respectively. Targets were localized to within 2.1 mm and 0.8° 95% of the time. The frequency of misalignments in the y direction was significant ( p < 0.05 ) when compared to the x and z directions with no significant difference in translations between IMRT and VMAT. This technique is robust using BodyFIX for patient immobilization and reproducible localization of kidney and adrenal targets and daily CBCT image guidance for correction of positional errors to maintain treatment accuracy. PACS number(s): 87.55.‐x, 87.56.‐v, 87.56.Da

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here