Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high‐dose‐rate brachytherapy for breast cancer
Author(s) -
Kim Yongbok,
Trombetta Mark G.
Publication year - 2014
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1120/jacmp.v15i1.4429
Subject(s) - nuclear medicine , medicine , brachytherapy , breast cancer , balloon , rotation (mathematics) , radiation therapy , radiology , cancer , mathematics , surgery , geometry
The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high‐dose‐rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7   cm for A; only rib spacing was ≤ 0.7   cm for B. Thirty‐five rotation scenarios were simulated for each patient by rotating outer lumens every 10° over ± 180 ∘range with respect to central lumen using mathematically calculated rotational matrix. Thirty‐five rotated plans were compared with three plans: 1) original multidwell multilumen (MDML) plan, 2) multidwell single‐lumen (MDSL) plan, and 3) singledwell single‐lumen (SDSL) plan. For plan comparison, planning target volume for evaluation (PTV_EVAL) coverage (dose to 95% and 90% volume of PTV_EVAL) (D95 and D90), skin and rib maximal dose (Dmax), and normal breast tissue volume receiving 150% (V150) and 200% (V200) of prescribed dose (PD) were evaluated. Dose variation due to device rotation ranged from − 5.6 % to 0.8% (A) and − 6.5 % to 0.2% (B) for PTV_EVAL D95; − 5.2 % to 0.4% (A) and − 4.1 % to 0.7% (B) for PTV_EVAL D90; − 2.0 to 18.4% (A) and − 7.8 to 17.5% (B) for skin Dmax; − 11.1 to 22.8% (A) and − 4.7 to 55.1% (B) of PD for rib Dmax, respectively. Normal breast tissue V150 and V200 variation was < 1.0   cc , except for − 0.1 to 2.5 cc (B) of V200. Furthermore, 30° device rotation increased rib Dmax over 145% of PD: 152.9% (A) by clockwise 30° rotation and 152.5% (B) by counterclockwise 30° rotation. For a highly asymmetric dose distribution, device rotation can outweigh the potential benefit of improved dose shaping capability afforded by multilumen and make dosimetric data worse than single‐lumen plans unless it is properly corrected. PACS number: 87.53.Jw

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here